Charder MS21NEOV User Manual Download Page 1

 

 

 

                            

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER MANUAL 

MS21NEOV 

Infant  Scale 

 

 

 

 

  Please keep the instruction manual at hand all the time for future reference.

 

Summary of Contents for MS21NEOV

Page 1: ...1 USER MANUAL MS21NEOV Infant Scale Please keep the instruction manual at hand all the time for future reference...

Page 2: ...for 2019 Separate collection for waste of electrical and electronic equipment in accordance with Directive 2002 96 EC Indicates that device conforms to 93 42 EEC as amended by 2007 47 EC Medical Devi...

Page 3: ...rnational copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liable for any damage caused by a failur...

Page 4: ...Indicator 21 A Indicator and Key Functions 21 B Display layout 22 IV Using Device 23 A Basic Operation 23 B Hold 23 C BMI 23 D Tare 24 E Pre Tare 24 F Print 28 V Device Setup 29 A Setting Time Date 2...

Page 5: ...y surface Usage on soft surfaces ex carpet may result in inaccurate results Ensure all parts are properly locked and tightened before operating the device Safety Instructions Before putting device int...

Page 6: ...routine maintenance However regular checking of accuracy is recommended frequency to be determined by level of use and state of device If results are inaccurate please contact local distributor Warran...

Page 7: ...able and avoid sharp edges Do not overload extension cables connected to the device Route cables carefully to avoid tripping Keep device away from liquids Do not remove the plug by yanking on the cabl...

Page 8: ...idance RF emissions CISPR 11 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic...

Page 9: ...pital environment Surge IEC 61000 4 5 1kV line s to line s 2kV line s to earth 1kV line s to line s 2kV line s to earth Mains power quality should be that of a typical commercial or hospital environme...

Page 10: ...0 AM at 1 kHz 3 V m 80MHz to 2 7 GHz Portable and mobile RF communications equipment should be used no closer to any part of the device including cables than the recommended separation distance calcul...

Page 11: ...e MS21NEOV Infant Scale The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the device can help prevent electr...

Page 12: ...12 II Installation A Assembly Column 1 Fasten and tighten three screws securing column with base 2 Fasten and tighten four screws to secure panel at bottom of base...

Page 13: ...13 3 Insert adjustable foot into base panel Turn counter clockwise to extend clockwise to retract Tray Assembly 1 Slide tray onto measurement platform...

Page 14: ...14 3 Slide tray onto measurement platform reverse view 4 Tighten side screws to secure tray to platform Turn clockwise to tighten counter clockwise to loosen...

Page 15: ...15 B Inserting Batteries 1 Open battery housing cover 2 Accessing batteries 3 Use either rechargeable battery pack or AA batteries Take out the battery housing...

Page 16: ...lled into the housing correctly 5 Install the battery housing into the compartment and make sure the right side of housing pin is facing towards inside of the connecting position Rechargeable Battery...

Page 17: ...s of if the device has been used Battery can be charged by plugging device s exclusive adapter into AC Connector Port After a long period in storage e g 3 months the battery should run a full cycle ch...

Page 18: ...18 C Using Adapter 1 Connect adapter to indicator before connecting to mains power supply 2 Disconnect adapter from mains power supply before unplugging adapter pin from indicator AC Connector Port...

Page 19: ...19 D Attaching Height Rod to Device 1 Attach bracket SS 5611 to tray with two screws 2 Slide height Rod onto bracket...

Page 20: ...20 3 Push until secure 4 Assembly complete...

Page 21: ...p to 5 4 PRE TARE Pre tare the known weight of an object ex chair before beginning measurement 5 TARE Allows user to deduct weight from reading after measurement 6 PRINT When printer or PC is connecte...

Page 22: ...22 B Display layout Definitions Stable symbol Indicate that weight is stable Zero symbol Weight is at zero Minor weight Weight under zero Low battery Battery needs to be charged or replaced...

Page 23: ...is too severe average weight determination will be difficult and hold may not function correctly 1 Switch on the device normally 2 Press the HOLD key HOLD will be displayed on the indicator 3 Carefull...

Page 24: ...d use separate standards for interpretation in comparison with percentile charts for their age group D Tare The tare function allows the user to deduct the weight of objects from the device s measurem...

Page 25: ...3 seconds A Load Weight DESCRIPTION EXAMPLE Press M1 5 key after loading weight on the platform the indicator will display blinking m symbol Press numeral key 1 5 to assign this number with the curren...

Page 26: ...hile digit is blinking Enter pre tare weight using 0 9 keys Ex to pre tare 5 0 kg of weight press 0 0 5 0 Ex to pre tare 13 5 kg of weight press 0 1 3 5 Press ENTER key to confirm the pre tare weight...

Page 27: ...ake a beep sound C Recall Pre Tare Weight DESCRIPTION EXAMPLE Press and hold PRE TARE key for 3 seconds Indicator will display pre tare value M1 first The pre tare value will flash Press numeral keys...

Page 28: ...tare weight must be under max capacity otherwise screen will show 0 00 after ENTER key is pressed and the operator will have to re input pre tare settings F Print If thermal printer is connected to in...

Page 29: ...onth followed by day using numeral keys 0 9 Ex December 25th is 12 25 Input 1 2 2 5 Press HOLD key once completed to proceed to time setting Time Setting Enter time 24hr format using numeral keys 0 9...

Page 30: ...ut off automatically after a certain period of time Auto off options 120 sec 180 sec 240 sec 300 sec off Press HOLD to toggle between time options and TARE to confirm selection Buzzer Beep When functi...

Page 31: ...ff Press HOLD to toggle between on off and TARE to confirm selection Wi Fi optional If device has Wi Fi module installed Wi Fi function can be turned on or off Press HOLD to toggle between on off and...

Page 32: ...ata Manager can be used to connect the device to a PC The software program can be downloaded from the Charder website LINK URL https www chardermedical com download htm 2 Connect USB cable to device i...

Page 33: ...BMI calculation into software if needed Press Clear to clear all input NOTE information can also be input after weight measurement 2 Conduct measurement If Auto is selected results will be transmitte...

Page 34: ...hanges and multiple measurements for the same subject we recommend not changing the default file name 2 Result example If previous results were saved in 20190201 csv new results also need to be saved...

Page 35: ...ng a printer connected to the PC VII Wireless Connection If the device has the wireless or bluetooth module installed the indicator can transmit measurement results wirelessly Please see Charder wirel...

Page 36: ...ng chemical electrochemical or electrical interference unless damage is attributable to negligence on the part of Charder If device is not covered under warranty a service maintenance charge will appl...

Page 37: ...software is set up properly as indicated in this manual Distributor support required If the following errors occur we recommend contacting your local Charder distributor for repair or replacement ser...

Page 38: ...Please contact distributor Counting Error too low Signal from loadcells too low Error normally caused by faulty loadcell or wiring Please contact distributor Zero count over calibration zero range 10...

Page 39: ...Hold Pre Tare Tare Clear Enter 0 9 M1 5 Power Supply Rechargeable battery pack optional or 6 AA batteries adapter Operation Temperature Humidity 0 40 15 85 RH Transportation Storage Temperature Humid...

Page 40: ...40 B Power Adapter Standards Warning The device is only compatible with the power adapters specified in the dashed block below...

Page 41: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...

Page 42: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...

Page 43: ...________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________...

Page 44: ...directives 93 42 EEC as amended by 2007 47 EC Medical Device Directive 2014 31 EU Non automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE ma...