Pump operates but 
delivers little or no 
water 

1. Plugged impeller 
2. Check valve 
installed backwards, or 
faulty 
3.  Pump air locked 

1. Clean out impeller 
2. Reverse position of 
check valve, or replace 
 
3. Drill 1/8” hole in 
discharge line between 
pump and check valve 

 

 

     

Model   CPS3 

 

    

Submersible Sump/Effluent Pump 

 

     

Thank you for purchasing this

 

CHAMPION PUMP

!

 The CPS3 is 

a high quality, energy efficient, heavy duty cast iron 1/3 HP sump/effluent 
pump.   We back these

 Champion 

products with 

Champion

 service and a 

Champion

 attitude.  Please read, save, and follow these instructions to 

ensure 

Champion

 performance. 

         

 

Product Warranty 

Date of Manufacture and Warranty Tag is on pump cord. 

 

LIMITED WARRANTY:  

 We warrant to our immediate customer and to the 

ultimate consumer that products of our manufacture will be free of defects 
in material and workmanship under normal use and service for one year 
(12 months) from the date of installation, or 18 months from the date of 
manufacture, which ever comes first.  We will repair or replace, at our 
option, to the original purchaser any part or parts of our product found 
upon our examination to be defective.  Please call Champion Pump 
Company, Inc. (419-281-4500) for instructions.  Be prepared to provide 
the model number, the date code and/or serial number and proof of the 
date installed when exercising this warranty.  Warranty tag (Required) is on 
the pump power cord.  All transportation charges on products or parts 
submitted for repair or replacement must be paid by purchaser.  This 
limited warranty does not cover products which have been damaged as a 
result of accident, abuse, misuse, neglect, improper installation, improper 
maintenance, or failure to operate in accordance with Champion Pump 
Company, Inc. written instructions.  

UNDER NO CIRCUMSTANCES WILL WE 

BE RESPONSIBLE FOR ANY OTHER DIRECT OR CONSEQUENTIAL 
DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, LOST 
INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION 
WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN MATERIAL AND/OR 
WORKMANSHIP AND/OR DAMAGE OR DELAYS IN SHIPMENT.  THIS 
WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED 
WARRANTY, INCLUDING ANY WARRANTY OF MERCHANTABILTIY OR 

FITNESS FOR A PARTICULAR PURPOSE.  

Some states do not allow 

limitations on how long an implied warranty lasts, or do not allow the 
exclusions or limitations of incidental or consequential damages, so the 
above limitations might not apply to you.   This limited warranty gives you 
legal rights, and you may also have other legal rights which vary from state 
to state. 

 

12-0010-0000 

 

 

 

     www.championpump.com

 4                                        05/12

 

 

BEFORE OPERATION – Important Product and 

Safety Information – 

WARNINGS – 

Personal Injury 

and/or property damage could result if not adhered to. 

 

!

 

Risk of Electric Shock – Fatal electric shock could occur.  Always 
disconnect the power source before attempting to install, service, 
relocate, or check the pump.  Never touch pump, pump motor, 
water, or discharge piping when pump is connected to electrical 
power.  Never enter a wet or flooded area, basement, basin, etc. 
that is in contact with the pump or electrical circuit before power 
supply has been disconnected. 

!

 

Pump has not been investigated for use in swimming pool areas 
or any area that might reasonably expect aquatic, animal, or 
human entrance.  Precautions should be taken to prevent such 
entrance during use. 

!

 

Connect only to a properly grounded, grounding type receptacle.  
Use of a ground fault circuit interrupter (GFCI) is required for 
maximum safety. 

!

 

All wiring must be performed by qualified electrician in 
accordance with all local and national electric code. 

!

 

When power source or supply is turned off (in open position) a 
lock and tag out should be used to prevent accidental power 
application or activation. 

!

 

Do not use extension cord or cut off grounding pin.  Should be 
installed on separate 15 AMP circuit breaker. 

!

 

Use only with a properly sized (input AMPS, volts, HP) motor 
controller. 

!

 

Do not use to pump flammable/explosive liquids such as 
gasoline, fuel oil, kerosene, and /or chemicals, salt water, etc. 

!

 

Do not use pump in an explosive atmosphere or classified as 
hazardous per NEC, ANSI/NFPA 70. 

!

 

Make sure pump is on hard level bottom in sump, do not set 
directly on earth, gravel, or other debris.  This could cause 
excessive wear or possible jamming and flooding. 

!

 

Make sure pump is secure in basin and piping is firmly supported 
so that pump cannot move, not allowing liquid level switch to 
interfere with basin wall or other obstacle preventing proper 
operation.  Flooding or overheating could occur if not prevented. 

!

 

 

 