100592 - 6250W DUAL FUEL GENERATOR
V
IMPORTANT SAFETY INSTRUCTIONS
10
Quickstart Label Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of
these symbols will allow you to more safely operate the product.
Starting the Engine
DANGER
Move generator outside and far away from windows,
doors and intake ventilation covers.
1.
Check oil level.
Recommended oil is 10W-30.
2.
Add fuel.
Check gasoline level. When adding gasoline, use
a minimum octane rating of 87 and an ethanol content of
10% or less by volume.
3. Turn fuel select dial to the
“GASOLINE RUN”
position.
4. Move the choke lever the
“CHOKE”
position.
5. Pull the recoil cord.
6. Move the choke lever to the
“RUN”
position.
7. Plug in desired device.
Stopping the Engine
1. Turn off and unplug all connected electrical loads.
2. Turn the fuel select dial to the
“ENGINE STOP”
position.
For adding fuel and starting the engine with LPG see
Add Fuel:
Propane (LPG)
in
Assembly
section and
Starting the Engine:
Propane (LPG)
in the
Operation
section.
10W-30
2
1
7
6
5
4
3
2
1
2688-L-PR