INSTALLATION STEP 7
Install the Light and Lens
INSTALL THE LIGHT
• Install an A19 standard neck, 75 watt maximum
light bulb in the socket. The light will turn ON and
remain lit for approximately 4-1/2 minutes when
power is connected. Then the light will turn OFF.
• Use standard neck Garage Door Opener bulbs for
replacement
INSTALL THE LENS
• Locate and loosen (approximately 1/8" (3 mm) the
two screws near top of opener front panel.
• Position lens against panel with slotted tabs
directly below screws. Slide lens up to seat tabs
behind screws.
• Snap bottom tabs of lens into panel slots.
• Retighten top panel screws to secure lens.
INSTALLATION STEP 8
Attach the Emergency Release
Rope and Handle
• Thread one end of the rope through the hole in the
top of the red handle so "NOTICE" reads right side
up as shown. Secure with an overhand knot at
least 1" (2.5 cm) from the end of the rope to
prevent slipping.
• Thread the other end of the rope through the hole
in the release arm of the outer trolley.
• Adjust rope length so the handle is 6 feet (1.83 m)
above the floor. Secure with an overhand knot.
NOTE:
If it is necessary to cut the rope, heat seal
the cut end with a match or lighter to prevent
unraveling.
To prevent possible SERIOUS INJURY or DEATH from a
falling garage door:
• If possible, use emergency release handle to disengage
trolley ONLY when garage door is CLOSED. Weak or
broken springs or unbalanced door could result in an
open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope
knot becomes untied, you could fall.
Lens Slot
75
W
att Max.
Light B
u
l
b
Lens Ta
b
Light
Lens
Panel Scre
w
Trolley
NOTICE
O
v
erhand
Knot
Emergency
Release Handle
Rope
Trolley
Release Arm
WARNING
CAUTION
WARNING
WARNING
To prevent possible OVERHEATING of the endpanel or
light socket:
• DO NOT use short neck or specialty light bulbs.
• DO NOT use halogen bulbs. Use ONLY incandescent.
To prevent damage to the opener:
• DO NOT use bulbs larger than 75W.
• ONLY use A19 size bulbs.
WARNING
CAUTION
WARNING
WARNING