This instruction manual ...

... describes the installation and operation of the roller shutter rotary switch. Please read this manual thoroughly. In addition pay attention to the safe-

ty instructions before you begin any work. Please store this manual. Guarantee will not be extended to damages arising from the non-observance of 

these instructions and the safety regulations. We are not liable for consequential damages resulting from it.

Here it is about safety.

Please observe and follow all instructions marked in this way.

By turning the red adapter the touch function can be switched to touch/latch function.

1. Touch version is created when the adapter with the small opening (1) is pushed up to the stop 

over the lug.

2. Touch/latch version is created when the adapter is turned 180° and with the large opening (2) is 

pushed up to the stop over the lug.

RZ94-05

The product is in compliance with the essential requirements and other relevant provisions of 

Directive 2014/35/ EC, 2014/30/EC. The CE Declaration of Conformity can be obtained from 

[email protected]

en

Roller shutter rotary switch

Danger to life through electric shock.

This sign points out the dangers while working on electrical connections, components, etc.

Safety measures are necessary for the protection of health and life of the affected people.

Danger to life through electric current! The roller shutter rotary switch should be installed and connected only by qualified electricians.

For this, pay attention to the guidelines of the VDE and the local electricity provider.

Danger through over voltage! Secure the device on site with a line circuit breaker of max. 10 A. Wire roller shutter rotary switch for 

the required application. Only one motor per roller shutter rotary switch. By the use of two or more motors it can be destroyed (please 

pay attention to manufacturer‘s specifications). The use of defective devices can lead to bodily injury and property damage (electric 

shock, short circuit). Therefore never use defective or damaged devices.

Before beginning the installation, make sure the power supply line is disconnected.

Technical Data

Mains voltage:

230V

Nominal current:

10A

Connections:

max. 2,5mm

1

P

2

Adapter

Lug

Base

touching and latching

57

51,5

64,5