background image

4

2

3

1

WHT

-2

RED

-1

5

6

6mm

1

2

4

WHT

RE D

1

4

LOCK

LIGHT

3

3

2

3

21

Multi-function Door Control: Press the white square to open or close the door. Press again to stop the door while it is
moving.
Light Feature: Press the Light button to turn the opener light on or off. If you turn it on and then activate the opener, the
light will remain on for 2-1/2 minutes. Press again to turn it off sooner. The Light button will not control the opener lights
when the door is in motion.
Lock Feature: Prevents operation of the door from portable remote controls. However, the door will open and close from
the Door Control push button, the Outside Keylock and the Keyless Entry Accessories.

To Activate: Press and hold the Lock button for 2 seconds. The push button light will flash as long as the Lock feature
is

on.

To turn off: Press and hold the Lock button again for 2 seconds. The push button light will stop flashing. The Lock feature
will also turn off whenever the “LEARN” button on the control panel is activated.

12

2

Install Door Control (optional)

Locate door control where the garage door is visible, away from door and door hardware and out of the reach of
children. Mount at least 1.5 m (5 feet) above the floor
Serious personal injury from a moving garage door may result from misuse of opener. Do not allow children to
operate the door control or remote control transmitter.
Permanently fasten the caution label permanently to the wall near the door control as a reminder of safe
operating procedures.
There are 2 terminals (1) on the back of the door control (2). Strip about 6mm (1/4") of insulation from bell wire (4).
Separate wires enough to connect the white/red wire to RED terminal screw 1 and the white wire to WHT terminal screw
2.
Fasten the door control to an inside garage wall with sheet metal screws (3) provided. Drill 4mm (5/32") holes and use
anchors (6) if installing into plasterboard wall. A convenient place is beside the service door and out of reach of children.
Run the bell wire up the wall and across the ceiling to the garage door opener. Use insulated staples (5) to secure wire.
The receiver quick connect terminals are located behind the light lens of the opener. Connect the bell wire to the terminals
as follows: white/red to red (1) and white to white (2).
Operation of the Door Control
Press to open or close the door. Press again to stop the door while moving.

Summary of Contents for Merlin MT60

Page 1: ...Instruction Manual for MT60 Sectional and Tilt Garage Door Motor Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 Chamberlain New Zealand Ltd P O Box 100 221 North Shore 0745 www chamberl...

Page 2: ...e installed This accessory allows manual operation of the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or stic...

Page 3: ...he Protector System 30 8 required See your dealer Tools Required 2 3 Before You Begin 1 Look at the wall or ceiling above the garage door The header bracket must be securely fastened to structural sup...

Page 4: ...Spring 20 Flat Washer 21 Stop Bolt Hardware Provided 3 1 Header Sleeve 2 Idler Pulley Bracket 3 Trolley 4 Rail 5 Chain 6 Hanging Bracket 7 Power Cord 8 Opener 9 Light Lens 10 Manual Release Rope Handl...

Page 5: ...inner trolley 2 into back opener end of rail assembly 3 be sure to insert idler pulley bracket as shown Arrow on trolley 7 must face toward front header end of rail 4 Push idler pulley bracket toward...

Page 6: ...n bolts securely The opener sprocket teeth must engage the chain CAUTION Use only those bolts mounted in the top of opener Use of any other bolts will cause serious damage to opener 4 7 6 3 Attach Spr...

Page 7: ...m You can attach the header bracket either to the header wall 1 or to the ceiling 3 Follow the instructions which will work best for your particular requirements With the door closed mark the vertical...

Page 8: ...to vertical center and horizontal lines created in step 12 for proper placement of header bracket A Wall Mount Center the header bracket 1 on the vertical center line 2 with the bottom edge of the hea...

Page 9: ...erent Hanging brackets 1 should be angled Figure A to provide rigid support On finished ceilings Figure B attach a sturdy metal bracket not supplied 4 to a structural support before installing the ope...

Page 10: ...fuser up until engaged Replace burnt out bulbs with heavy duty light bulbs 19 1 2 A 0 100mm B 150 250mm 3 4 7 6 2 1 4 5 3 A 4 B 7 6 A B 1 4 C 1 2 3 3 1 2 4 10 1 2 1 2 1 2 3 3 1 2 4 4 1 4 3 Fasten Door...

Page 11: ...ect the inner and outer trolley Slide the outer trolley back toward the opener and join the curved arm 2 to the connector hole in the trolley 8 with clevis pin 6 It may be necessary to lift the door s...

Page 12: ...is visible away from door and door hardware and out of the reach of children Mount at least 1 5 m 5 feet above the floor Serious personal injury from a moving garage door may result from misuse of ope...

Page 13: ...the Multi Function Door Control 4 Press and hold the button on the hand held remote that you wish to operate your garage door 4 5 While holding the remote button press and hold the LIGHT button on th...

Page 14: ...are held 7 Release buttons when the opener light blinks It has learned the code If the light bulb is not installed two clicks will be heard LOCK LIGHT LOCK LIGHT 24 Optional Motion Detecting Control P...

Page 15: ...travel to the UP open position The LED 3 indicator light will stop flashing when the force has been learned The door must travel through a complete cycle UP and DOWN in order for the force to be set p...

Page 16: ...es The force as measured on the closing edge of the door should not exceed 400 N 40kg If the closing force is more than 400 N the Protector System must be installed After opener has been installed and...

Page 17: ...Remote Control 6 Model C840 Keyless Entry System 7 Model C98 Motion Detecting Control Panel 8 Model 760 Outside Keylock 9 Model CM1702 Outside Quick Release 10 Model C77 The Protector System 11 Model...

Page 18: ...178B69 41B4616 4A1008 1 2 109A46 1 83A11 41A5643 3 12VDC Pb Cd Hg 12B380 12C778 41A5800 12C855 183D177 183D178 41A5887 001A5060 15 10A20 216A206 31D536 31D533 41A5843 41A5799 210C42 12C777 144C77 146...

Page 19: ...41A5735C 111A79 204C0161 2 41D577 108C82 41A5908 41A5797 158A49 031D0587 32 19...

Page 20: ...steps 25 and 26 Repeat the safety reverse test after the adjustment is complete 11 Opener light does not turn on Replace light bulb 24V 21W maximum Replace burned out bulbs with rough service light bu...

Page 21: ...and back toward the opener To reconnect the door pull the release handle straight down Do not use the manual release handle to pull the door opener or closed When the Opener is Activated by Remote Con...

Page 22: ...Unit that it is free from defects in material and or workmanship for a period of 2 YEARS from the date of first purchase from the Seller Please retain your proof of purchase in the unlikely event you...

Reviews: