Failure to comply with the following instructions may result in serious personal injury or property damage.
• Read these instructions carefully
• The garage door opener is designed and tested to offer reasonable safe service provided it is installed and operated in strict

accordance with the instructions in this manual.

These safety alert symbols mean 

Warning

– a personal safety or property damage instruction. Read these instructions carefully.

Warning: 

If your garage has no service entrance door, Model 1702E Outside Quick Release must be installed. This accessory allows manual

operation of the garage door from outside in case of power failure.

Keep garage door balanced

Do not let the garage door

opener compensate for a binding or sticking garage door.
Sticking or binding doors must be repaired. Garage doors,
door springs, cables, pulleys, brackets and their hardware
are under extreme tension and can cause serious personal
injury. 

Do not attempt to loose, move or adjust them.

Call for

garage door service.

Do not wear rings, watches or loose clothing 

while

installing or servicing a garage door opener.

To avoid serious personal injury from entanglement,

remove all ropes connected to the garage door 

before

installing the door opener.

Installation and wiring must be in compliance with your
local building and electrical codes. 

Connect the power

supply cord only to properly earthed mains. 

Lightweight doors of fiberglass, aluminum or steel
must be substantially reinforced to avoid door damage.

(See page 6.) The best solution is to check with your
garage door manufacturer for an opener installation rein-
forcement kit.

The safety reverse system test is very important.

Your

garage door 

MUST

reverse on contact with a 40mm obsta-

cle placed on the floor. Failure to properly adjust the open-
er may result in serious personal injury from a closing
garage door. 

Repeat the test once a month and make

any needed adjustments.

This unit should not be installed in a damp or wet
space.

Door must not extend over public byway during opera-
tion.

Start by Reading These Important Safety Instructions

The Protector System must be installed when the
force at the edge of the closing door force exceeds
400N (40kg). 

Excessive force will interfere with the proper

operation of the Safety Reverse System or damage the 
garage door. 

Permanently fasten the

caution label 

adjacent to the wall-

mounted door control control button as a reminder of safe
operating procedures.

Disengage all existing garage door locks 

to avoid dam-

age to garage door.

Install the lighted door control button (or any additional
push buttons)

in a location where the garage door is

visible, at a height of at least 1.5m and out of the
reach of children. Do not allow children to operate
push button(s) or remote control(s).

Serious personal

injury from a closing garage door may result from misuse
of the opener.

Activate opener only when the door is in full view, free
of obstructions and opener is properly adjusted. No
one should enter or leave the garage while the door is
in motion. Do not allow children to play near the door.

Use manual release

only 

to disengage the trolley and, if

possible, 

only 

when the door is closed.

Do not use the

red handle to pull the door open or closed.

Disconnect electric power to the garage door opener
before making repairs or removing covers.

This product is provided with a power supply cord of spe-
cial design which, 

if damaged, must be replaced by a

power supply cord of the same type

; such a power sup-

ply cord may be obtained and fitted by a specialist.

CONTENTS

PAGE

SAFETY RULES . . . . . . . . . . . . . . . . . . . . . . . .

1

DOOR TYPES  . . . . . . . . . . . . . . . . . . . . . . . . .

2

TOOLS REQUIRED  . . . . . . . . . . . . . . . . . . . . .

2

HARDWARE PROVIDED  . . . . . . . . . . . . . . . . .

2

BEFORE YOU BEGIN  . . . . . . . . . . . . . . . . . . .

1

COMPLETED INSTALLATION  . . . . . . . . . . . . .

2

ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . .

2-4

CONNECT ELECTRIC POWER  . . . . . . . . . . .

3

PROGRAMMING THE CODE  . . . . . . . . . . . . .

4

ADJUSTMENT  . . . . . . . . . . . . . . . . . . . . . . . . .

5

CONTENTS

PAGE

INSTALL THE PROTECTOR 
SYSTEM (OPTIONAL)  . . . . . . . . . . . . . . . . . . .

5

SPECIAL FEATURES . . . . . . . . . . . . . . . . . . . .

5

ACCESSORIES  . . . . . . . . . . . . . . . . . . . . . . . .

5

REPLACEMENT PARTS  . . . . . . . . . . . . . . . . .

see Instruction 

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

sheet

CARE OF YOUR OPENER  . . . . . . . . . . . . . . .

6

MAINTENANCE OF YOUR OPENER  . . . . . . .

6

HAVING A PROBLEM?  . . . . . . . . . . . . . . . . . .

7

OPERATION OF YOUR OPENER  . . . . . . . . . .

6

SPECIFICATIONS  . . . . . . . . . . . . . . . . . . . . . .

6

WARNING

BEFORE YOU BEGIN:

1. Look at the wall or ceiling above the garage door. The header bracket 

must

be securely fastened to structural supports.

2. Do you have a finished ceiling in your garage? If so, a support bracket and additional fastening hardware (not supplied) may be required.

3. Depending on your door's construction, you might need a special door arm. See your dealer.

4. Do you have an access door in addition to the garage door? If not, Model 1702E Outside Quick Release Accessory is required. This accessory

allows manual operation of the garage door from outside in case of power failure.

1-en

Summary of Contents for LM1000A

Page 1: ...LM1000A Instruktie LM800A LM1000A Instrucciones LM800A LM1000A Manuais LM800A LM1000A Istruzioni LM800A LM1000A LM800A LM1000A Instruktioner LM800A LM1000A Instruksjonene LM800A LM1000A Instruktioner...

Page 2: ...Excessive force will interfere with the proper operation of the Safety Reverse System or damage the garage door Permanently fasten the caution label adjacent to the wall mounted door control control b...

Page 3: ...il 5 Insert carriage bolt 6 through header sleeve bracket 7 Loosely thread spring nut 8 and flat washer 9 onto carriage bolt Insert carriage bolt 6 of header sleeve assembly 7 into bold cut out in pul...

Page 4: ...nging brackets with screw lock washer and nut 3 Check to make sure rail is centered over the door REMOVE 25mm 1 board Operate door manually If door hits the rail raise header bracket Use rail grease a...

Page 5: ...this or other rolling code garage door openers OPEN CLOSE STOP OPERATION only if you have a Multifunction door control Your remote control can be programmed to operate one door using all 3 buttons th...

Page 6: ...or must reverse on the obstruction If the door stops on the obstruc tion remove obstruction and repeat Setting the Limits step 26 Repeat test When the door reverses on the 40mm obstacle remove the obs...

Page 7: ...artially open or closed position it will reverse direction 5 If an obstruction is encountered while closing the door will reverse 6 If an obstruction is encountered while opening the door will reverse...

Page 8: ...ngaged all door locks Review installation instruction warnings on page 1 Is there a build up of ice or snow under door The door may be frozen to ground Remove any obstruction The garage door spring ma...

Page 9: ...owner for the repair and or replacement parts and or product Defective parts will be repaired or replaced with new or factory rebuilt parts at Chamberlain s option If during the warranty period the p...

Page 10: ...12 1 2 3 12 4 6 9 8 9 11 13 14 7 15 10 7 9 1 2x 5 2 2x 2 2x 4 2x 6 2x 5 2x 15 1x NOTICE 5 1x 1x 10 2x 13 2x 3 4x 7 4x 8 4x 9 4x 14 3x 10x 11 2x 12 2x 16 1x 17 2x 4 8 7 6 9 10 1 6 7 10 Chamberlain GmbH...

Page 11: ...12V DC Pb Cd Hg 12B380 41A5639 7 10A20 41A5800 210C42 183D177 183D178 7423CR3 12C855 171A28 31D525 41A5801 1 1 7m 41A5801 2 3m 41A5801 2 2 5m 41A5801 3 3 0m 31D537 41A5844 2 3m 41A5844 1 2 5m 41A5844...

Reviews: