Chamberlain LIFTMASTER MUGAPLM User Manual Download Page 1

Carton Inventory

Overview

The Multi-Unit Gate Access Panel (MUGAPLM) uses 
a digitally secure intercom link that allows it to control 
up to four gate operators and other accessories. It 
can be used with up to 63 homes and program up to 
120 remote control transmitters.
The MUGAPLM is compatible with various LiftMaster 
Wireless Products.

Multi-Unit Gate Access Panel (MUGAPLM)

1

MUGAPLM Installation & 
Assembly

Model MUGAPLM

Multi-Unit Gate Access Panel

Bolt (4)

Washer (4)

Nut (4)

Key (2)

Step 1

Choose mounting location for MUGAPLM. Remove 
the back panel and attach it to a solid surface or post.

Step 2

Install 4 C batteries (not provided) in the MUGAPLM 
and it will beep until the Master PIN Number is 
entered.

Step 3

On keypad press:

Step 4

Enter 4 digit Master PIN Number. Example: 1234.

Step 5

Mount the MUGAPLM onto the back panel. Lock 
MUGAPLM with key.

NOTE:

 Do not slam the MUGAPLM against the wall 

or the temper sensor will activate.

If additional MUGAPLM is being used see 

Operation 

& Features: Multi-GAP Mode.

#

#

#

?

?

?

?

NOTE:

 “ * “ is a cancel button that will cancel any call 

or key sequence.

“BEEP” “BEEP”

Telephone Interface Unit (OTIU):

 The 

OTIU allows the user to identify which 
gate or door a visitor is at with Caller ID 
and a distinctive ring tone. To answer a 
call press “0”. A gate can be opened by 
dialing “*9” on the telephone keypad.

Accessory Overview

Portable Intercom: 

The intercom allows 

the user to speak with visitors at the 
MUGAPLM and open the gate by holding 
the Remote button for 10 seconds.

Flush Mount Intercom:

 The intercom 

allows the user to speak with visitors at 
the MUGAPLM.

Repeater Set: 

Repeaters are used to 

extend the range between the 
MUGAPLM and other devices. They are 
recommended for use with buildings with 
stucco or cement walls.

Remote Control Transmitter:

 The 

remote control transmitter will open the 
gate when the numbered button is held 
down for 5 seconds within 75' of the 
MUGAPLM.

®

NOTE:

 To prevent damage to the circuit DO NOT use 

C size Lithium batteries or rechargeable batteries. If 
Lithium batteries are needed, switch the C battery 
pack with the provided AA battery pack.

Multi-Unit Telephone Interface 
(MUOTIU):

 The MUOTIU acts as a 

wireless remote autodialer in a dedicated 
line system.

Summary of Contents for LIFTMASTER MUGAPLM

Page 1: ...Mode NOTE is a cancel button that will cancel any call or key sequence BEEP BEEP Telephone Interface Unit OTIU The OTIU allows the user to identify which gate or door a visitor is at with Caller ID an...

Page 2: ...LED Within 20 seconds enter Master PIN Number on MUGAPLM Followed by GCU Identity as determined in Step 3 1 2 3 4 OR OR OR The GCU LED will blink 3 times indicating programming is successful NOTE The...

Page 3: ...trol device that will be used to access the LiftMaster door or gate operator Program Indicator Light Learn Button Erase All Control Codes Press and hold the Learn button on the receiver until the Indi...

Page 4: ...light Step 4 The LED s on the second set of Repeaters will flash three times indicating programming is successful NOTE If adding Repeaters to existing network all accessories that have been programmed...

Page 5: ...N number you want to remove A triple beep indicates a PIN Number has been entered that does not exist The Master PIN Number cannot be deleted A temporary PIN Number can be used only once within a 24 h...

Page 6: ...ence from conflicting radio transmitters Any accessories programmed to the MUGAPLM will have to have memory cleared and be reprogrammed Enter Master PIN Number on MUGAPLM 5 5 Enter one of the followin...

Page 7: ...Setting BEEP BEEP The AA batteries not provided in the GCU will last up to a year and a half depending on use Lithium batteries recommended for colder environments If batteries are low the intercom w...

Page 8: ...in GCU see GCU Installation Manufacturer s Reset Code is needed to reset MUGAPLM The MUGAPLM s serial number is printed on the inside of the MUGAPLM s back panel Call Technical Support at 1 800 528 28...

Page 9: ...de interfaz del tel fono OTIU La OTIU permite al usuario identificar en qu puerta o entrada est el visitante con el identificador de llamada y un tono de llamado distintivo Para responder una llamada...

Page 10: ...por un segundo El LED se encender durante 20 segundos LED En menos de 20 segundos ingrese el n mero de PIN principal en el MUGAPLM Luego ingrese la identificaci n de la GCU como se determina en el Pa...

Page 11: ...e control que se usar para acceder al operador de puerta o acceso LiftMaster Programaci n Borrar todos los c digos de control Presione el bot n Aprendizaje en el receptor y no lo suelte hasta que la l...

Page 12: ...NO de los repetidores delprimer juego de repetidores El LED se encender Paso 4 Los LED del segundo juego de repetidores parpadear n tres veces lo que indica que la programaci n ha sido exitosa NOTA Si...

Page 13: ...que desea eliminar Una se al sonora triple indica que se ha ingresado un n mero de PIN que no existe El n mero de PIN principal no se puede eliminar Se puede usar un n mero de PIN temporal s lo una ve...

Page 14: ...dio Todo accesorio programado en el MUGAPLM deber tener la memoria limpia y reprogramada Ingrese el n mero de PIN principal en el MUGAPLM Ingrese uno de los siguientes canales O O El MUGAPLM se puede...

Page 15: ...terminada de GAP m ltiple BEEP BEEP Las bater as AA no incluidas en la GCU durar n hasta un a o y medio dependiendo del uso se recomiendan las bater as de litio para ambientes m s fr os Si las bater a...

Page 16: ...n los interruptores DIP 1 y 2 en la GCU ver Instalaci n de la GCU Es necesario el c digo de reinicio del fabricante para reiniciar el MUGAPLM El n mero de serie del MUGAPLM est impreso en el interior...