Chamberlain 922GA Install Manual Download Page 1

© 2007, The Chamberlain Group, Inc.

01-34285

All Rights Reserved

Mounting
Bracket

Batteries

Mounting
Screws

Control Board

 3

Ø

A    32V 

R91 

R94 

R93 

L1 

Battery 
Connector

AC PWR/
Solar PWR Input

CLOSE
EDGE

R93 

L1 

D42 

K2 

D1Ø 

OPEN EDGE/

PHOTO

OPEN
PHOTO

CLOSE
PHOTO

Z22 

P1 

F2 

MO

V1 

D1 

Q12 

U4 

CONTROL

INPUTS

FORCE

TIMER TO

CLOSE

OFF

MAX

OPEN

SINGLE BUTTON

RESET

STOP

SHADOW

INTERRUPT

CHGR
OVLD

COM

COM

CTRL

LOOP

INPUTS

D129 

Z4 

U

3

 

D2 

D44 

C11 

C13 

C12 

D16 

F9 

R1Ø1 

R1ØØ 

K1 

Q22 

F3 

K3 

K4 

R196 

F1 

Z12 

GATE 2

ACCESSORY

POWER

ALARM

GATE 1

MAGR

SOL

GR

WH

YL

BL

RD

BR

GR

WH

YL

BL

RD

BR

F7 

24V

CTRL
OVLD

TIMER

RUNNING

GATE 2

SET

OPEN
LIMIT

SET

CLOSE

LIMIT

LEARN
LIMITS

DIAGNOSTIC

GATE 1

LEARN

XMITTER

LOCK /

ON

OFF

PWR

C69 

OFF

MAX

J2
Ø 

PWR

SINGLE BUTTON

AC PWR
/SOLAR

D8 

D4 

R9 

R329 

R27 

MO

V2 

R4 

C2 

BIPART DELAY

LOCK

GND

Z1 

R1 

R2 

K5 

F12 

Q9 

R9Ø 

F8 

Q6 

Q1 

J19 

ACCESSORY

0VLD

R182 

C1Ø1 

C75 

C73 

C72 

C71 

C7Ø 

C66 

C65 

C68 

C33 

F11 

R186 

R42Ø 
R423 

J24      J23      3

Ø

A      32V 

 3

Ø

A    32V 

J21 

30 

30 

C64 

R22 

U2 

J18 

K6 

JU1 

JU2 

DB1 

D36 

R184 

Terminals
Blocks

Terminals

Blocks

Control Board

Battery 
Connector 
from battery

Battery 
Connector 
from Control Board

Coaxial Connector

GATE ACCESS SYSTEM BATTERY MODEL 922GA

INSTALLATION

1. Disconnect power.

2. Remove screws and open the control box.

3. Disconnect coaxial connector and all terminal blocks from the

control board.

NOTE:

For reinstallation, be sure to note the locations of all terminal

block connections.

4. Disconnect battery connectors.

5. Loosen mounting screws. Slide the mounting bracket with control

board up and remove. Set aside for reinstallation.

6. Attach new wire harness to the new battery. Install the new battery

in the control box.

7. Reinstall the control board and bracket, secure with mounting

screws.

8. Reconnect battery connectors. Verify the 

DIAGNOSTIC

LED blinks.

9. Reconnect all terminal blocks.

10. Reconnect power to operator.

11. Reinstall control box cover and secure with screws.

12. Verify gate operator functions properly.

The model 922GA is compatible with Chamberlain

®

Gate Access Systems

GA400D and GA420D. The Gate Access System Battery is designed to
add a battery for solar applications or as a replacement battery.

NOTE:

The Single Gate Access System model GA400D contains a single

battery only.

To reduce the risk of FIRE or INJURY to persons:
• Use ONLY Chamberlain part 922GA.
• DO NOT dispose of the batteries in fire. The cells may explode.

Check with local codes for possible disposal instructions.

• DO NOT open or mutilate the batteries. Released electrolyte is

corrosive and may cause damage to the eyes or skin. It may be
toxic if swallowed.

• Exercise care in handling batteries in order not to short the battery

with conducting materials such as rings, bracelets, and keys.

• Change the batteries provided with or identified for use with this

product ONLY in accordance with the instructions and limitations
specified in this manual.

• Observe proper polarity orientation between the batteries and

charging circuit.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

WARNING

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

Reviews: