Challenger SL04B Instructions Download Page 1

    

SL04B Instructions Rev01 

 

 

  MODEL: SL04B 

 

We are delighted that you have purchased this PIR Light. This light 
is  suitable  for  indoor  or  outdoor  use.  Please  read  this  instruction 
manual before installation and retain for future reference.  
IMPORTANT:  Never  modify  the  unit,  there  are  no  user  serviceable 
parts  inside.  Not  suitable  for  use  with  dimmer  switches.  Install  in 
accordance with IEC Wiring Regulations.  

THE LIGHT SHOULD BE INSTALLED BY A QUALIFIED 
ELECTRICIAN.
 

 

OCCUPANCY 

The  PIR  Sensor  has  an  Occupancy  Range  of  Radius  3  meters.  In  this 
range, the sensor will detect small movement. 
If you want to achieve best results, we suggest you take into account the 
following points: 
1.  The Occupancy Range is 3 meters. 
2.  We suggest the delay time must be set more than 10 minutes. 
3.  The  PIR  Sensor  must  worked  at  25˚c  or  lower  and  dry  weather 

(normal temperature) 

 

POSITIONING THE LIGHT 

When  selecting  the  mounting  position,  take  into  account  the 
following points: 

1. 

  The sensor is designed for optimum performance when mounted at a 

height of between 1.8.5 to 2.5  meters (see Figure 1) 

2. 

  Avoid pointing at or positioning close to heat sources such as heaters 

or heat extraction units, which may cause false triggering. 

3. 

  Avoid pointing at bright lights as the PIR sensor will not function when 

you set Lux control level to dark (  position). 

4. 

  Avoid  mounting  at  strong  electromagnetic  disturbance,  i.e.  near 

electrical motor or fluorescent lamp ballast.  

 

INSTALLING THE LIGHT 

Before commencing any electrical work, ensure the mains supply is 
isolated by switching off and removing the relevant fuse. (See Figure 
2 A ,B and C) 
A.B.  Wall and Ceiling Mounting(Figure 2A and B) 
1.  Use a screwdriver to remove the bottom 
2.  Remove the Junction Box and Terminal Block 
3.  Use  the  Bottom  Cover  to  mark  the  position  of  screw  holes  onto 

mounting  surface.  Drill  the  wall  to  depth  of  about  35mm  and  fit  the 
plastic plugs, and then fix the Bottom Cover to the mounting surface 
with rightly screws. Care should be taken to avoid drilling or screwing 
into concealed electrical wiring. 

Occupancy 3m

Fig.1 Detection Area

210¡ ã

1.8-2.5m

10m