![CG emotron TSA Series Instruction Manual Download Page 45](http://html1.mh-extra.com/html/cg/emotron-tsa-series/emotron-tsa-series_instruction-manual_2585387045.webp)
CG Drives & Automation 01-5980-01r2
Getting started
41
5.5
Control panel operation
A manual test run can be executed via the control panel.
This example demonstrates the set-up to carry out for a
standard motor.
Switch on the voltage
Once the control supply voltage is switched on, the system is
initiated, the display is lit and the internal fan (no fan in
frame size 1) will run for 5 seconds.
Set the basic data
Enter the basic data, i.e. language, time, and motor data for
the connected motor. Perform this the same way as for
“Remote I/O operation” on page 40.
Follow the steps 1 - 10.
Then press
until you return to menu [100],”Preferred
View”.
Select manual control
1. Press
to display menu [200], “Main Setup”.
2. Press
to display menu [210], “Operation”.
3. Press
until you get to menu [215] “Action Control”,
then press
to go to submenu [2151] “Run/Stop
Control”.
4. Select “Int keyb
”
using the key
.
Press
to confirm.
Test run from control panel
Press the
key on the control panel to run the motor
forward.
To stop the motor, press the
key on the control panel.
NOTE: When the internal bypass contactor is activated,
three distinct clicks are heard.
NOTE: For selection of other stop method than the
default “Coast”, see section 7.1.2, page 35 and menu
[341].
Summary of Contents for emotron TSA Series
Page 1: ...Emotron TSA Softstarter Instruction manual English Valid from Software version 1 27...
Page 2: ......
Page 4: ......
Page 6: ...2 CG Drives Automation 01 5980 01r2...
Page 12: ...8 Introduction CG Drives Automation 01 5980 01r2...
Page 18: ...14 Mounting CG Drives Automation 01 5980 01r2...
Page 42: ...38 Application guidelines CG Drives Automation 01 5980 01r2...
Page 46: ...42 Getting started CG Drives Automation 01 5980 01r2...
Page 70: ...66 Main features CG Drives Automation 01 5980 01r2...
Page 142: ...138 Functionality CG Drives Automation 01 5980 01r2...
Page 158: ...154 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5980 01r2...
Page 160: ...156 Options CG Drives Automation 01 5980 01r2...
Page 168: ...164 Technical data CG Drives Automation 01 5980 01r2...
Page 202: ...CG Drives Automation 01 5980 01r2 198...
Page 203: ......