22
Technical data
CG Drives & Automation 01-7513-11r0
4.
Technical data
4.1
Safety data
As determined by TÜV testing in accordance with EN ISO 13849-1 and IEC
61508-1 (see TÜV certificate, and based on the associated technical report no.
968/FSP 2222.00/21).
This Emotron OSTO_100 option is designed with designated Category 4 acc.
EN ISO 13849-1.
Safety parameters according to IEC 61508, part 1-7 and IEC
62061 Safety of machinery
NOTE: All calculations in this section are calculated based on a redundant
use case. If only a single channel is used the presented safety data below is
not valid.
Table 2
Safety parameters IEC 61508 and IEC 62061
Parameter
Value
Comment
Safety Integrity Level
(SIL / SIL CL)
3
PFH
D
> 4.96E-10
PFD
4.13E-05
Proof test interval
20 years
Mission time
Summary of Contents for Emotron OSTO 100