CG Drives & Automation 01-7513-11r0
Safety information
15
3. Check that no voltage is present
1
.
4. To secure that fuse will blow in case power turned back on by accident –
short & ground power interface.
5. Make sure that possible adjacent live parts are covered / made inaccessible
.
2.6
Repair and modifications
The user is NOT allowed to do electrically design changes to AC drives which
has the Emotron OSTO_100 option mounted as it is part of a safety solution.
Nor shall the safety function be disabled by any hardwiring of the safety inputs.
Neither repair nor modification of the Emotron OSTO_100 option board is
allowed. In case of suspected defect on option board, please return it to CG /
Emotron along with a detailed fault description.
2.7
Disposal
The enclosures of the drives are made from recyclable material as aluminum,
iron and plastic. Our AC-drives comply to RoHS II directive, and contain
electronic waste (e-waste). Any local or national regulations in force for the
disposal and recycling of e-waste must be complied with.
1. NOTE: Also consider/check residual voltage.
WARNING!
Always switch off the mains voltage before opening the AC and
wait at least 7 minutes to allow the capacitors to discharge.