Chapter XIV Waveform Generator (Option)
181
Fig. 15.10 WaveGen Menu (Pulse)
Frequency/Period
Click [Frequency] or [Period] key, and the Frequency/Period menu will pop up on the right side of the screen. The
Frequency or Period can be set, with the frequency adjustment range of 100 mHz
10 MHz and the period
adjustment range of 100 ns ~ 10 s.
Amplitude/High
Click [Amplitude] or [High] key, and the Amplitude/High menu will pop up on the right side of the screen. The
Amplitude or High can be set, with the amplitude adjustment range of 10 mV ~ 2.5 V and the high level
adjustment range of -1.245 V ~ 2.5 V.
Offset/Low
Click [Offset] or [Low] key, and the Offset/Low menu will pop up on the right side of the screen. The Offset or
Low can be set, with the offset adjustment range of -1.25 V~1.25 V and the low level adjustment range of -2.5 V ~
1.245 V.
Duty Cycle
Click [Duty] key, and the Duty menu will pop up on the right side of the screen:
Fig. 15.11 Duty Menu
Click [Duty] menu key to set the Duty through the Multipurpose b or numeric keypad, and the value range is
related to the pulse output frequency.
Click [Width] menu key to set the Width through the Multipurpose b or numeric keypad, and the value range is
related to the pulse output frequency, with the min. width of 40 ns.
Click [Leading] menu key to set the Leading through the Multipurpose b or numeric keypad, and the value range
is related to the pulse width, with the min. Leading of 20 ns.
Click [Trailing] menu key to set the Trailing through the Multipurpose b or numeric keypad, and the value range
is related to the pulse width, with the min. Trailing of 20 ns.
15.1.5 DC
Press down
【
WaveGen
】
key on the front panel, open the WaveGen menu, click [Waveforms] key, and open the
Waveforms menu on the right side of the screen. Click [DC] key, set the waveform to DC, and adjust the
WaveGen to corresponding menu of DC after selection:
Fig. 15.12 WaveGen Menu (DC)
Offset
Summary of Contents for 4456 Series
Page 10: ...VIII...
Page 55: ...Chapter V Trigger System 45 Fig 5 51 RF Test Signal Example...
Page 69: ...Chapter VII Mathematical Operation 59 Fig 7 10 Advanced Math Example...
Page 71: ...Chapter VIII Display System 61 Fig 8 3 Wfm Palette Menu Fig 8 4 Normal Palette...
Page 72: ...Chapter VIII Display System 62 Fig 8 5 Inverted Palette Fig 8 6 Temperature Palette...
Page 75: ...Chapter VIII Display System 65 Fig 8 12 XY Display Example...
Page 165: ...Chapter XI Protocol Analyzer Option 155 Fig 11 242 1553 Trigger and Analysis Example...