background image

C-net 2000 MULTI

User’s Guide

Issue 08 (V2 series software)

Summary of Contents for C-net 2000 MULTI

Page 1: ...C net 2000 MULTI User s Guide Issue 08 V2 series software...

Page 2: ......

Page 3: ...to the reliable world of Cetrek Autopilot and Control Systems Thank you for buying this C net 2000 MULTI It is designed to let you select the information that you want presented in the manner most su...

Page 4: ...ndards SMALL CRAFT ELECTRICAL SYSTEMS a ISO 10133 Extra Low Voltage DC Installations b ISO 13297 Alternating Current Installations ISO International Standards Organisation The information contained in...

Page 5: ...nformation 14 4 Multi Data Information 16 5 NAV Data Information 18 6 WIND Information 20 7 HEADING Information 22 8 Temperature Information 24 9 Battery Voltage Information 25 10 Configuration Settin...

Page 6: ...en The C net 2000 Multi has five soft keys whose function changes depending on the display in general the Grey keys change the displayed information and the Blue key adjusts viewing conditions There i...

Page 7: ...displays Ocean displays Speed Speed Depth Depth Water Temperature Water Temp Battery Voltage Battery Voltage Navigator Wind Heading Rudder Angle The information can each be displayed in many differen...

Page 8: ...to show the last viewed information display In this example the Speed Graph display When first pow ered up the C net 2000 Multi will carry out a self test routine Here is shown the software version Th...

Page 9: ...urrent information display 1 3 Lighting and Contrast Press the blue button while viewing an information display and the LCD lighting and contrast adjustment becomes available Adjust these to give the...

Page 10: ...onds the menu will slowly sink off the bottom of the screen Press any Grey button to recall the menu SPEED Graph DEPTH Graph MULTI Data 1 SPEED Gauge DEPTH Gauge MULTI Data 2 SPEED Big DEPTH Big MULTI...

Page 11: ...Plot WIND Angle HEAD Card WIND Big HEAD Pilot WIND Alarm HEAD Rudder WIND Digital Each press cycles through the NAV Displays Each press cycles through the Wind Displays Each press cycles through the...

Page 12: ...ED BIG A digital display using big characters SPEEDSTATISTICS Displays of the fastest and the average Speed since the C net 2000 Multi was powered up or reset Press any Grey key the menu will now have...

Page 13: ...imer starts counting up The timer will continue to run even if you switch to other displays until STOP is pressed Press the STOP key to stop the Race Timer Press the OK key to exit the SET TIMER contr...

Page 14: ...A digital display using big characters DEPTHSTATISTICS Displays of the deepest Depth recorded and the average Depth since the C net 2000 Multi was powered up or reset Press any Grey key the menu will...

Page 15: ...Grey key the menu will now have an ADJUST option Press the Blue key Used to change depth of the alarm Use to return to the previous menu Use to switch the alarm On or Off Press the OK key in each lev...

Page 16: ...y repeatedly to step through the options that can be displayed in that window Stop at the one required This selection will be stored for future use MULTI Data2 A second display of two windows adjusted...

Page 17: ...hrough the options that can be displayed in that window Stop at the one required This selection will be stored for future use MULTI Quad2 only on Ocean versions A second display of four windows adjust...

Page 18: ...an approaching waypoint The distance bearing and waypoint name is shown clearly at the top of the screen Also on the screen is the current water speed and depth reading The boat symbol at the bottom o...

Page 19: ...inputs allows the tidal stream to be measured NAV Plot A basic plotter screen showing the recent history of positions taken once per second An ADJUST mode provides a Zoom feature and the ability to st...

Page 20: ...ut with an amplified scale for close hauled and running The needle is three times more sensitive to changing wind angle in this mode WIND Stats A useful summary of the highest wind speed average wind...

Page 21: ...and enabled separately This is a global function in a system the setting can be changed on any Multi and it changes all in the system When an alarm is triggered it repeats on all MULTIs in the system...

Page 22: ...locked heading LOCK on or off and OCA off course alarm function If a heading is Locked and the vessel is slightly off course the bar graph above the tape repeater shows the direction and the amount o...

Page 23: ...est stored value and this can be fine tuned with the LESS and MORE keys HEADING Gauge A steering compass with a moving pointer and digital read out HEADING Card A steering compass with rotating card a...

Page 24: ...b thermometer representation of the Water Temperature with a small digital display TEMPERATURE BIG A digital display using big characters TEMPERATURESTATISTICS Displays of the highest and lowest recor...

Page 25: ...resentation of the voltage with a small digital display BATTERY BIG A digital display using big characters BATTERYSTATISTICS Displays of the highest and lowest recorded and the average Battery Voltage...

Page 26: ...the option you wish to change Use to adjust the selected option Units in this example a new menu will be displayed Use to exit the ADJUST option UNITS This option allows the setting of the following...

Page 27: ...e wind angle so that it reads correctly This adjustment also corrects any WIND or TACK units connected in the system only on Ocean versions This is used for directly connected compass systems that res...

Page 28: ...change to INT 2 3 As soon as the vessel starts to move in a clockwise direction the status will change to RUN 2 4 When the compass has completed its deviation turns the compass status will read CORR...

Page 29: ...B If set to LOCAL changing its lighting level will affect only that unit If set to GROUP A or B when the light level is changed on any MULTI in the same group all MULTI s in that group will change Tw...

Page 30: ...nput channels and the single output channel The messages are listed individually or all messages can be masked on or off with the all option Here all the NMEA messages are turned on for all channels H...

Page 31: ...opied across the CAN bus to other MULTIs and also to WIND or TACKs The Upload feature will be described with the upgrade kits The Self Test provides diagnostic information and has a very useful NMEA v...

Page 32: ...30293 Specifications Supply 12V nominal 10 5V to 15 0V max CAN link 30 units NMEA inputs 3 per unit NMEA outputs 1 per unit Dimensions 110mmx110mm 4 3 x 4 3 max Stud depth 7mm Weight 290g 9 3oz Operat...

Page 33: ...tely ventilated so that the rear sees the same ambient temperature as the front Most units will be mounted in a bulkhead and that method is described here A Trunnion mounting kit is also available Par...

Page 34: ...r TRANSDUCER DATA INPUTS NMEA 0183 instrument data can be connected to any spare input of any unit in the system with the exception of the Cetrek 3400 which cannot use NMEA 1 inputs Ensure only one so...

Page 35: ...ectors at the rear of this product are for the high speed CAN bus data link This operates at 250Kbit sec which is 52 times faster than NMEA 0183 MULTI WIND and TACK units can all be in one system in a...

Page 36: ...g details of the alarm condition Check the connections to the sensor equipment Check the sensor equipment itself DEPTH ALARM WIND ALARM and HEADING ALARM When an active Alarm is reached a pop up windo...

Page 37: ...000 Instruments read combine and output the following NMEA 0183 version 2 messages APA APB BOD BWC BWR DBT DPT GGA GLL HDG HDM HDT MTW MWV RMA RMB RMC RSA VHW VLW VTG VWR WAS WDC XTE Also used are two...

Page 38: ...ormation Display 7 Installation 33 Interference 34 K keys 7 L language 28 lighting 9 lighting group 29 lighting start up 29 Linkcables 35 location 33 M Menu Display Pop up 10 Sinking 10 menus 10 Mount...

Page 39: ......

Page 40: ......

Reviews: