© Cesab
8 – 59
T Code(s): 841, 842, 843
Repair manual: Troubleshooting
Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040
Date: 2018-05-01
Applies from serial number: 6384351-
8.11 Built-in test function for the tiller arm
1:
Make sure the battery is connected.
2:
Check that the truck is switched off. Press the OFF switch.
3:
Connect the CAN key or enter the PIN code. Note: Do not press the ON
switch.
4:
Press and then release the horn button. “Info“ is shown on the display.
5:
Press and release the horn button to select the "Info" menu.
6:
Turn the speed control several times until “tESt” is shown on the display.
7:
Press the horn button and release it to enter the test mode.
8:
The first one you arrive at is the display test. Press on the button/function
you want to test to proceed. In this mode, the 2 LEDs on the keypad
flash.
8.11.1 Display test
The digital display [A6] can be tested to verify all the segments of the display
function correctly. A moving 8 tests all the segments of the display.
8.11.2 Speed control
The Hall elements are tested by moving the speed control all the way back
and forth. Follow these steps to test the Hall elements:
Move the rocker from the neutral position to begin the test. This is visualised
as number X Y when the rocker is moved in the fork direction and X-Y when
the rocker is moved in the drive wheel direction. X is the total number of Hall
elements that are affected by the magnet and Y is the number of existing Hall
elements. At full movement in both directions 9-9 or 9 9 is shown when all Hall
elements are OK.
8.11.3 Safety reversing
Press the button for safety reversing “Er 1” is shown in the display
8.11.4 Controls for lifting/lowering
Press a button for lifting/lowering in order to start the test. “L1”, “L2”, “L3” or
“L4” is shown in the display depending on which button has been pressed.
https://www.forkliftpdfmanuals.com/