© Cesab
8 – 7
T Code(s): 841, 842, 843
Repair manual: Troubleshooting
Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040
Date: 2018-05-01
Applies from serial number: 6384351-
8.7 Error codes
Please note that some error codes are saved in the log and disappear from
the display, while other error codes remain on the display and require that the
truck be switched off and then on again for the error code to disappear.
Code
Description
Truck
behaviour
Error cause(s)
Procedure
2:002
Parameters set to
default values.
At start-up, it was
detected that one
or more
parameters were
not within
acceptable
intervals; they have
therefore been
reset to default
values
Not influenced
1:
New software
has
been
loaded in the
truck, adding a
new
parameter, or
it has changed
the parameter
limit values
2:
Corrupt
memory A5
1:
Check parameters
•
Check that factory parameters
are set according to the truck
configuration.
•
Check that other parameters
are set correctly.
2:
Replace A5:
2:004
Backup copies do
not match.
Backup copy in
secondary unit (T1)
does not match
data in primary unit
(A5)
Not influenced
1:
Hardware (T1
or
A5)
has
been
replaced.
2:
Software has
been updated
to an older
version
3:
Corrupt
memory T1
4:
Corrupt
memory A5
1:
Copy the truck configuration
using TruckCom
•
See the separate manual for
TruckCom.
2:
Copy the truck configuration
using TruckCom
•
See the separate manual for
TruckCom.
3:
Replace T1
4:
Replace A5
2:005
Internal program
error
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
Internal program
error A5
•
Create a truck report. Send a
report to the manufacturer.
•
Update the truck software to the
latest version.
https://www.forkliftpdfmanuals.com/