Cerner MDC-2 Operator'S Manual Download Page 1

o p e r a t o r s   m a n u a l

Includes mda-1

MDC-2

connectivity engine

Care

 

Aware  

Connection

Summary of Contents for MDC-2

Page 1: ...o p e r at o r s m a n u a l Includes MDA 1 MDC 2 Connectivity Engine Care Aware Connection...

Page 2: ...T 06460 2008 Cardiopulmonary Corp All Rights Reserved CARDIOPULMONARY CORP MDC 2 July 31 2008 2964 01 16 REV 03 Cerner Corporation 2800 Rockcreek Parkway Kansas City MO 64117 T 816 221 1024 www cerner...

Page 3: ...ing plainly worn distorted or contaminated should be replaced immediately This product or any of its parts should not be repaired other than by Cerner authorized service personnel The product must not...

Page 4: ...MDC 2 Operator s Manual ii...

Page 5: ...SAFETY 3 Electrical 3 Explosion 4 Radio Communication 4 Description of Warning Labels 6 DESCRIPTION 7 System Overview 8 Special Cables 9 Features 9 Fuse Ratings 10 Installation Operating Instructions...

Page 6: ...lation complies with all applicable regulations The equipment is used in accordance with the instructions in this manual Incorrect operation or failure of the user to maintain the MDC 2 in accordance...

Page 7: ...ection Do not attempt to defeat this protection by modifying the cable or by using ungrounded adapters or extension cables The power cord and plug must be intact and undamaged It is the user s respons...

Page 8: ...nitrous oxide EMC This equipment has been certified to be protected to emissions and immunity according to the EMC and R TTE Directives WARNING In a domestic environment this product may cause radio...

Page 9: ...this frequency Any change or modification not expressly approved by Cardiopulmonary Corp could void the user s authority to operate the device This device also meets the requirements of the Canadian...

Page 10: ...OMPANYING DOCUMENTS Equipment connected should comply with UL 60601 1 or IEC 950 with configuration to IEC 60601 1 1 Fuse type rating Mains Power On Mains Power Off Protective earth ground Functional...

Page 11: ...le medical device The MDC 2 is capable of connecting up to eight medical devices using USB cabling to the MDA 1 connector The MDA 1 is powered through the USB connection to the MDC 2 The MDA 1 is moun...

Page 12: ...MDC 2 Operator s Manual 38 99 99 81 MDA 1 MDA 1 MDA 1 MDA 1 HIS System Overview MDC 2...

Page 13: ...MDC 2 Operator s Manual RS232 To Medical Device USB To MDC 2 Special Cables...

Page 14: ...scription of Features LCD Touchscreen POWER ON Indicator Fuse Ratings The fuses are located behind the cover of the power entry module To replace the fuses remove the cover and replace them only with...

Page 15: ...button on the rear panel of the MDC 2 Turn it on The boot up sequence may take up to approximately 60 seconds The system is ready to use once the WindowsCE and Bernoulli splash screens disappear and t...

Page 16: ...emperature Range 20 C to 40 C Relative Humidity 0 90 non condensing Atmospheric Pressure 500 1060 mbar Power Requirements Voltage Input 100 230 VAC 47 63 Hz without manual switching Maximum AC Power C...

Page 17: ...orage Temperature Range 20 C to 40 C Relative Humidity 0 90 non condensing Atmospheric Pressure 500 1060 mbar Power Requirements Voltage Input 5 V Maximum DC Power Consumption Derived from USB Cable 1...

Page 18: ...ss or rub the display and covers with abrasive cleaning compounds instru ments brushes rough surface materials or bring them into contact with anything that could scratch the display or the covers Do...

Page 19: ...MDC 2 Operator s Manual 15...