Installation Guide for FibeAir IP-20S, FibeAir IP-20S Assured
Page 64 of 105
Ceragon Proprietary and Confidential
5.
Generic Installation Procedures and Notes
5.1
Torque Requirements
When tightening the captive screws, use 20 Nm torque for radio-antenna, radio-
mediation device, and mediation device-antenna connections. In order to avoid
misalignment, screws should be tightened progressively.
When fastening a waveguide to the radio or mediation device, use the following
torque, according to frequency and screw type:
•
6 GHz: M5/#10-32: 3.5 Nm
•
7/8-15 GHz: M4/#8-32: 2.5 Nm
•
18-42 GHz: M3/#4-40: 1Nm
5.2
Pole Mount Installation
The pole diameter range for pole mount installations is 8.89 cm
–
11.43 cm (3.5
inches
–
4.5 inches).
5.2.1
IP
-
20S DC Pole Mount Procedure
List of Items
Item Description
Quantity Remarks
1
IP-20S DC POLE MOUNT KIT
1
Required Tools
•
Metric offset wrench key wrench set
Procedure
1 Mount and tighten the IP-20S DC pole mount to a pole with a diameter of 114
mm using the four washers and screws supplied with the IP-20S DC pole
mount kit.