Table 49: LLDP Read-Only Configuration Parameters
Parameter
Definition
Max TX Credit
Displays the maximum number of consecutive LLDPDUs that can be
transmitted at any one time. In this release, the Max TX Credit is set at 5.
Fast TX Interval (Seconds)
Displays, in seconds, the interval at which LLDP frames are transmitted
during fast transmission periods, such as when the unit detects a new peer.
In this release, the Fast TX Interval is set at 1.
Fast TX
The initial value used to initialize the variable which determines the number
of transmissions that are made during fast transmission periods. In this
release, the Fast TX No. is set at 4.
Reinit Delay (Seconds)
Defines the minimum time, in seconds, the system waits after the LLDP
Admin status becomes Disabled until it will process a request to reinitialize
LLDP. For instructions on disabling or enabling LLDP on a port, see
Configuring the LLDP Port Parameters.
In this release, the Reinit Delay is set at 2.
Table 50: LLDP Configurable Configuration Parameters
Parameter
Definition
TX Interval (Seconds)
Defines the interval, in seconds, at which LLDP frames are transmitted. You
can select a value from 5 to 32768. The default value is 30.
Notification Interval (Seconds)
Defines the interval, in seconds, between transmission of LLDP notifications
during normal transmission periods. You can select a value from 5 to 3600.
The default value is 10.
Hold Multiplier
Defines the time-to-live (TTL) multiplier. The TTL determines the length of
time LLDP frames are retained by the receiving device. The TTL is
determined by multiplying the TX Interval by the Hold Multiplier.
You can select a value from 2 to 10. The default value is 4.