FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 191 of 597
Table 42: Ethernet TX Port PMs
Parameter
Definition
Interval
For 24-hour intervals, displays the date of the interval. For 15-minute intervals,
displays the date and ending time of the interval.
Peak... Average... bytes...
Packets...
Various peak transmission rates (in seconds) and average transmission rates (in
seconds), both in bytes and in packets, for each measured time interval.
TX bytes Layer 1 exceed
threshold (sec)
The number of seconds the TX bytes exceeded the specified threshold during the
interval. For instructions on setting the threshold, see Setting the Ethernet Port TX
Threshold.
Invalid data flag
Indicates whether the values received during the measured interval are valid. An x
in the column indicates that the values are not valid (for example, because of a
power surge or power failure that occurred during the interval).
To clear the PMs, click Clear All.
6.5.2.2 Enabling or Disabling Gathering of Port TX PM Statistics per Interface
To select the interfaces for which to gather and display Port TX PMs:
1 In the Ethernet Port TX PM Report page, click PM Admin. The Ethernet PM
Port Admin page opens.
Figure 134: Ethernet PM Port Admin Page
2 Select the interface.
3 Click Enable Port PM or Disable Port PM to enable or disable the
gathering of Port TX PMs on the selected interface.
4 Click Close.