FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 103 of 597
Figure 68: SNMP Parameters Page
2 In the Admin field, select Enable to enable SNMP monitoring, or Disable
to disable SNMP monitoring.
Note:
The Operational Status field indicates whether SNMP
monitoring is currently active (Up) or inactive (Down).
3 In the SNMP Read Community field, enter the community string for the
SNMP read community.
4 In the SNMP Write Community field, enter the community string for the
SNMP write community
5 In the SNMP Trap Version field, select V1, V2, or V3 to specify the SNMP
version.
Note:
The SNMP MIB Version field displays the current SNMP
MIB version the unit is using.
6 In the V1V2 Blocked field, select Yes if you want to block SNMPv1 and
SNMPv2 access so that only SNMPv3 access will be enabled.
7 Click Apply.
If you are using SNMPv3, you must also configure SNMPv3 users. SNMPv3
security parameters are configured per SNMPv3 user.