23.4.4
Radio LED
The Radio LED indicates the status of the radio link:
•
Off
–
The radio is off; all carriers are Admin = Disabled in the Interface
Manager.
•
Green
- The power is on, and all carriers are operational (up).
•
Orange
–
A signal degrade condition exists on at least one carrier.
•
Red
- A loss of frame (LOF) or excessive BER condition exists on at least one
carrier.
23.4.5
Status LED
The Status LED indicates the status of the main board:
•
Off
–
The power is off.
•
Green
- The power is on, and no alarms are raised on the motherboard.
•
Orange
–
The power is on, and one or more minor alarms or warnings are
raised on the motherboard.
•
Red
- The power is on, and one or more major or critical alarms are raised on
the motherboard.
23.4.6
Protection LED
The Protection LED operates in a protected configuration to indicate the
protection status:
•
Red
–
A protection alarm exists (cable disconnected, mismatch configuration,
or mate communication not working). Note that only the active unit will have
a red LED.
•
Orange
-Protection is enabled, and the unit is in standby mode.
•
Green
- Protection is enabled, the unit is in active mode, and no protection
alarms are present.
•
Off
–
Protection is not enabled.