To display the same information without the last RX error CCM and fault
messages, enter the following command in root view:
root> ethernet soam mep status general show meg-id <meg-id>
mep-id <mep-id> detailed no
The
Last RX error CCM message
field displays the frame of the last CCM that
contains an error received by the MEP.
The
Last RX Xcon fault message
field displays the frame of the last CCM that
contains a cross-connect error received by the MEP.
Note:
A cross-connect error occurs when a CCM is received from a remote
MEP that has not been defined locally.
22.9.3.7
Performing Loopback (CLI)
To set the interval between loopback message transmissions in a loopback
session, enter the following command in root view:
root> ethernet soam loopback interval set meg-id <meg-id> mep-
id <mep-id> interval <0-60000>
For example, the following command sets the loopback interval for MEP 25 on
MEG 1 to 5 seconds:
root> ethernet soam loopback interval set meg-id 1 mep-id 25
interval 5000
To set the loopback message frame size and data pattern, enter the following
command in root view:
root> ethernet soam loopback data set meg-id <meg-id> mep-id
<mep-id> size <size> pattern <pattern>