User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 492 of 825
Ceragon Proprietary and Confidential
3 To switch back to the active unit, enter the following command:
mate/root> switch-back
root>
14.6.7
Viewing Link and Protection Status and Activity (CLI)
You can view link and protection status and activity any time.
•
To view whether HSB protection is enabled or disabled, enter the following
command in root view:
root> platform management protection show admin
•
To view whether HSB protection is functional (available in practice), enter the
following command in root view. Note that protection is not functional if
MIMO is configured, or if the management connection to the mate is down.
root> platform management protection show operational-state
•
To view protection activity, enter the following command in root view:
root> platform management protection show activity-state
•
To view the status of the protection link to the mate, enter the following
command in root view:
root> platform management protection show link-status
•
To view the status of the last copy-to-mate operation, enter the following
command in root view:
root> platform management protection show copy-to-mate status
•
To view the current lockout status, enter the following command in root view:
root> platform management protection show lockout status
14.6.8
Manually Switching to the Standby Unit (CLI)
The following events trigger switchover for HSB radio protection according to
their priority, with the highest priority triggers listed first.
1 Loss of active unit
2 Lockout
3 Radio/Ethernet interface failure
4 Manual switch
At any point, you can manually switch to the Standby unit, provided that the
highest protection fault level in the Standby unit is no higher than the highest
protection fault level on the Active unit.
To manually switchover to the Standby unit enter the following in root view:
root> platform management protection set manual-switch
14.6.9
Disabling Automatic Switchover to the Standby Unit (CLI)
At any point, you can perform lockout, which disables automatic switchover to
the standby unit.
To disable automatic switchover to the Standby unit, use the following command
in root view: