User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 188 of 825
Ceragon Proprietary and Confidential
7 In the
Member role
field, select the role of the interface in the AFR 1+0
configuration:
◦
If you are configuring the Hub site, select
Aggregate #1
or
Aggregate #2
.
◦
If you are configuring the Tail site, select
Tail #1
or
Tail #2
.
Make sure
the interface you configure as Aggregate #1 is part of the link with
Tail #1 and that the interface you configure as Aggregate #2 is part of the link
with Tail #2.
8 Select
Set MRMC Script (1801)
.
Note:
Script 1801 is a 28/30 MHz script, with a maximum ACM profile of 10
(2048 QAM). For additional details, refer to the relevant Release Notes
or product Technical Description.
9 In the
MRMC Script maximum profile
field, select the maximum ACM profile
for the links.
10 Click
Finish
. This page displays the parameters you have selected for the link.
Figure 131: AMCC Group
–
Selection Summary Page
11 Click
Submit
. The unit is automatically reset. Once AFR has been configured on
the Hub site and both Tail sites, the configuration is complete.