User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 165 of 825
Ceragon Proprietary and Confidential
3.7.5
Viewing the Configuration of the Standby unit
You can view the settings of the standby unit any time.
To view the settings of the standby unit, click the
Standby
tab of the desired page.
The following is an example of the
Standby
tab of the Radio Parameters page
after
Protection Admin
has been enabled.
Figure 105: Standby Tab of Radio Parameters Page
3.7.6
Editing Standby Unit Settings
Almost all settings of the standby unit are view-only. However, several settings
are editable on the Standby unit. They must be configured separately for the
Standby unit, and are not copied via copy-to-mate, nor do they trigger a
configuration mismatch in the CLI.
In the Web EMS, failure to synchronize these configuration settings causes a
configuration mismatch alarm.
The following settings must be configured separately on the standby unit:
•
Setting the Unit Name
–
in the
Name
field of the Unit Parameters page (see
).
•
Disabling/enabling Radio TX-mute
–
in the
TX mute
field of the Edit Radio
Configuring the Radio Parameters
•
Clearing the Radio and RMON counters
–
in the
TX mute
field of the
. Refer to
Displaying and Clearing Defective Block Counters
•
Setting the activation key configuration
–
in the
Activation Key
and
Demo
admin
Activation Key Configuration Page
(see
).
•
Defining user accounts
–
Access Control User Accounts Page
(see
•
Setting synchronization settings
–
).