User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 140 of 825
Ceragon Proprietary and Confidential
3.4.3
Multiband Management
The IP-20E unit in a Multiband configuration can be managed normally, as in any
other configuration. For in-band management of the IP-20E, configure the
management service on the IP-20E Multiband group. See
The following options are available for managing the IP-20C or IP-20S unit in a
Multiband configuration:
•
Inband management via the IP-20E
•
Inband management directly from the external switch
•
Out-of-Band management
3.4.3.1
Inband Management via the IP-20E
The IP-20C or IP-20S unit can managed via the IP-20E. In-band management via
the IP-20E requires an ESS hardware version for IP-20C (two SFP ports). To
manage the IP-20C or IP-20S via the IP-20E, an optical cable must be connected
between port Eth3 on the IP-20E and Eth3 on the IP-20C or IP-20S.
Since Eth2 and Eth3 on the IP-20E are accessed via a single gland on a single
physical port, a special cable must be used. This cable fits into the single gland on
the IP-20E in order to connect to both Eth2 and Eth3. On the IP-20C or IP-20S side
of the cable, the cable is split so that a separate cable can be inserted into the
gland for Eth2 and the gland for Eth3.
IP-20C or
IP-20S
Eth2
Eth3
IP-20E
Port 2
(CSFP)
Eth2
Eth3
Figure 86: Multiband Cable for Use with CSFP Port
Table 18: Multiband Cable for Use with CSFP Port
Cable Marketing Model
Cable Description
IP-20_FO_SM_LC2SNG2LC_ARM_5m
CABLE,FO,DUAL LC TO LC/LC SPLIT,5.3M,SM,3xM28
GLAND,OUTDOOR