Menu 4 - Modes of Operation
Menu 5 - Run profile
Refer to “Select Operating Mode” on page 17 for an explanation of the four
different Modes of Operation available: Simplex, Complex, PLC and Spike.
Refer to “Select Operating Mode” on page 17 for an explanation of the four
different Modes of Operation available: Simplex, Complex, PLC and Spike.
&
Lock boom pole at endpoints:
!
Lock When Raised
- mechanically lock boom pole in raised position. Use
manual override key to override
!
Lock When Lowered
- as per above for lowered position
The locking endstops must be accordingly set for locking to take
effect. Refer to installation manual
!
Holding Force
- force used to automatically hold the boom pole in the raised
or lowered position if “lock at endpoints” is
not
selected
!
Raise When Mains Fail
If enabled, the boom pole will raise in event of a mains power failure. Boom
pole will remain raised until mains power is restored
!
Spike Interface
If enabled, this facility allows the
SECTOR
controller to communicate with co-
installed roadway spikes, such as CLAWS.
!
Pre-raising Delay
Allows a delay between a valid trigger signal and the boom pole raising. Can
activate warning light during delay if TVI is not selected. (Refer to pre-flash
modes of the Courtesy Light feature, for more details.)
!
Pre-lowering Delay
Identical to above, except for boom pole lowering
!
Raising Speed
Sets the maximum raising speed in degrees per second
!
Ramp-up Distance
Sets the ramp-up distance in degrees
!
Ramp-down Distance
Sets the ramp-down distance in degrees of travel of the boom pole when
stopping
!
TRG Stop Distance
Sets the distance over which a moving boom pole will stop after a trigger
signal is received