42009085-013 R1

The Programmer should be mounted at a level where the 
display can be seen clearly and the ambient temperature is 
within the range of 0 to 45°C.  The unit is for use in normal 
domestic environments.

To remove the unit from the 
wallplate, slacken the two securing 
screws and hinge the unit up to 
separate the two halves.

CAUTION:

 Isolate power supply and 

make safe before wiring the unit to 
prevent electric shock and equipment 
damage. Installation should be 
carried out by a qualified electrician 
or competent heating engineer.

Installation Guide

for EHE0200160 Programmer

Introduction 

EHE0200160 is an Electronic Full Programmer providing accurate 
time control for central heating installations with separate 
programmes for heating and hot water. It can be used to 
program a heating schedule for weekdays (Monday – Friday) and 
weekends (Saturday and Sunday) independently.

Specification 

Power Supply : 

230V~, 50…60Hz, 8VA

Switch Action : 

2 x SPDT

Switch Rating : 

230V~, 50…60Hz, 3(3)A

Timing Accuracy :  ±1min./month
Power Reserve : 

typically 4 days

Approvals : 

CE marked

Mounting

Mounting Options

Heating

Hot Water

ON-OFF

OVERRIDE EXTRA HOUR

Mon

Tue

Wed

Thu

Fri

Sat

Sun

ON-OFF ON-OFF

RECOMMENDED CLEARANCE DISTANCES:

ABOVE WALLPLATE: 

40mm

BELOW WALLPLATE: 

100mm

LEFT/RIGHT OF WALLPLATE: 

10mm

b. Flush switchbox Fixing 

holes are spaced to suit 

BS4662 requirements

c. Surface mounting with 

surface wiring in 

mini trunking

a. Surface mounting 

concealed wiring

Wiring

A switch, having contact separation of at least 3mm in all poles 

(formerly Class ‘A’), must be incorporated in the fixed wiring as 

a means of disconnecting the supply.
The unit is a Class II (double insulated) device.  An earth 

terminal is provided for external earth continuity.
The system must be appropriately fused.  A fuse rated at no 

more than 3 Amps should be installed.
The unit has 4 knockouts for surface wiring, care must be taken 

to ensure that the cable or mini-trunking completely fills the 

knockout hole without leaving any gaps.

ALL WIRING MUST BE IN ACCORDANCE WITH I.E.E. 

REGULATIONS.  THIS UNIT IS FOR FIXED WIRING ONLY.

Replacing Other Manufacturers’ Time Controls

This Programmer will mount directly onto many existing 
manufacturers’ back-plates, without the need for re-wiring. 
However, it is also supplied complete with a wiring 
back-plate, should this not be the case.