21. FAULT DETECTION IN THE APPLICATION:
The simplest way to objectively detect if there are faults in the application is to observe the
spraying, which is affected by the following parameters:
Temperature: A material that is too hot will produce separation in the fan. A material
that is too cold will produce a ripple effect.
Pressure: Too high a pressure will result in excessive or disaggregated spraying. A
pressure that is too low will produce a ripple effect.
Contamination of the products in the mixing chamber.
A foreign object in the mixing chamber will cause bad fanning.