28
CHV-320 TECHNICAL MANUAL
03-2022
Translation of the original manual
18.
DAILY STOP SEQUENCE
.
1. Close the stopcock taps on both products on the gun.
2. Activate the gun trigger two or three times to clean
9
.
3. Deactivate heating in the hose with the stop pushbutton
10
.
4. Deactivate heaters with the stop pushbutton.
5. Deactivate the cylinder with the stop pushbutton.
6. Open the stopcock taps on the products in the gut and pull the trigger several times
until the pressure in the products decreases below 435 psi (see output pressure gages)
and check that the pump Piston rods are at their lowest position and fully insert them
inside the body of the pump in order to guarantee autolubrication.
7. Deactivate the pump with the stop pushbutton.
8. Disconnect the main switch.
9. Close the stopcock taps for products on the gun and pull the trigger 2 or 3 times.
10. Close the air stopcock on the gun.
11. Dismantle the side and front housings of the gun for cleaning. Lubricate with Celtipol
grease
11
.
12. Close the main compressed air valve on the machine.
13. Electrical disconnection of the machine.
9
Observe if there are
any losses in the
injectors by repeatedly
activating the trigger .
10
The hoses with hot
products should not be
bled under no
circumstance.
11
Never dismantle the side blocks on the gun with
the product taps open since the gun may fill up with
foam and be a risk for the user.
Summary of Contents for CHV-320
Page 38: ...38 CHV 320 TECHNICAL MANUAL 03 2022 Translation of the original manual 26 ELECTRICAL DIAGRAMS ...
Page 39: ...39 CHV 320 TECHNICAL MANUAL 03 2022 Translation of the original manual ...
Page 40: ...40 CHV 320 TECHNICAL MANUAL 03 2022 Translation of the original manual ...
Page 41: ...41 CHV 320 TECHNICAL MANUAL 03 2022 Translation of the original manual ...
Page 52: ...52 CHV 320 TECHNICAL MANUAL 03 2022 Translation of the original manual 30 CE DECLARATION ...
Page 53: ...53 CHV 320 TECHNICAL MANUAL 03 2022 Translation of the original manual ...