background image

TECHNICAL SPECIFICATION 

Model:   

CELDH200 

Supply:    

220-240VAC 50Hz 

Wattage: 

330-440W 

Unit Capacity:  

20L/day max (30°C/80%RH) 

Tank Capacity:   2.0L 
Refrigerant:  

R134a/180g 

 
PROOF OF PURCHASE 

To receive warranty retain receipt as proof of purchase. (Refer to back of booklet). 

Problem 

Cause 

Solution 

The Dehumidifier will not turn 
on 

The power is not connected 

Insert plug into mains power 
supply and turn unit on 

The Dehumidifier is not 
extracting water 

The water tank is full 

Remove the water tank and 
empty water 

The water tank is not in its 
correct position 

Remove water tank and 
replace it correct position 

The air filter is clogged 

Clean the air filter as per 
instructions in user manual 

The temperature or relative 
humidity in the room is too 
low 

It is normal for the 
Dehumidifier not to operate in 
low humidity or low 
temperatures 

The Dehumidifier operates, 
but reduces the relative 
humidity in the room by small 
amounts 

The room which the 
Dehumidifier is operating in is 
too large 

Recommend using a 
Dehumidifier with a larger 
capacity 

There are too many sources 
of humidity 

Recommend using a 
Dehumidifier with a larger 
capacity 

The room has too much 
ventilation 

Reduce the number of 
ventilation sources (i.e. close 
windows, doors, etc. 

TROUBLESHOOTING 

Summary of Contents for CELDH200

Page 1: ...per day in an environment of 80 humidity and temperature of 30 C This is the world wide standard for rating dehumidifiers In New Zealand we do not have climatic conditions with humidity and high tempe...

Page 2: ...plug 16 Always unplug appliance when not in use 17 Do not locate the Dehumidifier directly below any power socket during operation 18 Do not twist kink or wrap the cord around the appliance as this ma...

Page 3: ...COMPONENTS Water Tank Handle Control Panel Filter Continuous Dehumidify Drain Air Outlet Front Cover Air Guide Louvre Power Cord CONTROL PANEL...

Page 4: ...the RH cannot be adjusted in this mode Press the STANDBY button again to turn the unit off NOTE When the sensor detects an ambient humidity level 1 lower than the current set level the compressor will...

Page 5: ...t Do not operate with the Air Guide Louvre closed DEFROST When the Dehumidifier is operating in low temperatures under 12 C the unit will go into a defrost cycle once an hour This is to remove any ice...

Page 6: ...If this option is desired you will need to purchase a suitable tube from your local hardware retailer Celsius does not hold tubes as spare parts Connect the drainage hose to the drain spout and ensur...

Page 7: ...in its correct position Remove water tank and replace it correct position The air filter is clogged Clean the air filter as per instructions in user manual The temperature or relative humidity in the...

Page 8: ...that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are a...

Reviews: