11
V3.15.22
・
Mount the unit in the upright position close to the ceiling inside the cellar.
As warm air rises to the top of the cellar, the cooling unit pulls the warm air
through the evaporator coil and removes the heat from the warm air. Once cooled,
the cold air is discharged from the front of the cooling unit and circulates through
the cellar.
・
Slide the unit through from the outside of the cellar.
CAUTION:
Two people are required to move the cooling unit, which is very heavy. Do
not place the cooling unit on unprotected bottle racks.
・
Tilt the cooling unit slightly backwards.
The rear of the cooling unit should
be
slightly lower
than the front of the cooling unit to facilitate the flow of excess
condensate to the drain line.
・
Use our adjustable mounting brackets to support and anchor the cooling
unit to the framing in the wall.
Use the (12) #10x1-1/2” flat Phillips head wood
screws provided to anchor the screws into the studs and braces. The mounting
brackets can be used either inside or outside the cellar and can be used in three
different locations, as shown below.