ISSUE 4.0
6.0 INSTALLATION
INSTRUCTIONS
6.1
Using a 301-037 security tool (sold separately), loosen and remove the
security screws.
6.2
The security tool is for a standard 5/32" button head screw generally used
on the framework of the phone booths.
6.3
Separate the telephone assembly from the mounting or housing.
Mountings or housings should be installed as is appropriate for each
particular item and installation. Be sure that installation is done in
accordance with all applicable laws and codes.
6.4
Run the inside station wire through the mounting or housing and terminate
on to the RJ11C terminal block.
6.5
The use of a gas tube station protector is recommended. The station
ground should not exceed 50 ohms.
6.6
Plug the modular line cord from the telephone assembly into the RJ11C
terminal block.
6.7
Dress the line cable away from hardware, which might cause damage to
the cabled. Secure the telephone assembly by installing and tightening the
security screws.
6.8
When servicing the phone, be sure the PC board does not contact metal
parts, otherwise permanent damage may occur to the board.
*****WARNING*****
A. Never install telephone wiring during a lightning storm.
B.
Never install telephone jacks in wet locations unless the jack
is specifically designed for wet locations.
C. Never touch uninsulated telephone wires or terminals
unless the telephone line has been disconnected at the
network interface.
D.
Use caution when installing or modifying telephone lines.
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
9