background image

                                                                               

 

 

 

 

 

OPERATION MANUAL

 

 

 

TORQUE TESTER

 

 

 

MODEL 

 

CD-100M/10M

 

 

 

 

1571 
 

Summary of Contents for CD-100M

Page 1: ...OPERATION MANUAL TORQUE TESTER MODEL CD 100M 10M 1571 ...

Page 2: ...nt of Electric Driver 9 4 1 1 Check of Torque and Selection of Measurement Joint 9 4 1 2 The method of measurement 9 4 2 Measurement of Torque Driver Torque Wrench 10 4 2 1 Measurement of a torque driver 10 4 2 2 Measurement of Torque Wrench 10 5 About a convenient function 11 5 1 Kind of Convenient Function 11 5 2 The setting method of a convenient functional numerical value 11 5 3 How to Use Con...

Page 3: ...g from power supply When not using or charging When fixing When danger can be expected in addition to this 8 Check whether there is not any damaged portion Check whether there is not any damage before use enough and it checks whether it operates normally or a predetermined function is demonstrated Check whether there are not any abnormalities in all the parts that do influence in case of use Perfo...

Page 4: ...impossible posture Always brace a step and maintain balance 4 Work being careful enough without being inattentive When using the product it carries out by being careful enough of the method of dealing with it the method of work a surrounding situation etc It is not used when it is tired within the limits of common sense Since it has written that it is common in all of products of our company there...

Page 5: ... joint for measurement is attached or the angle of a tool is inserted and it measure Numerical Setting Mode Determination Key It is used when changing the setting numerical value of various functions It is used when determining a numerical value Measurement Unit Key It is used when changing the unit of measurement Key UP Key It is used when making a numerical value increase at the time of a functi...

Page 6: ...second A change whole 1 12 seconds is possible Data memory Measured value 800 data Data output ASCII format baud rate 19200 Automatic clear time In 0 1 3 0 seconds 0 5 seconds interval an indication is automatically given zero It is a manual zero clearance by 0 0 second setup One touch zero By pushing a clear button zero adjustment can be performed by one touch Battery Ni cd battery 1 2V 5sells 70...

Page 7: ...nation T R track There is no display It is mainly used at the time of calibration etc The value of the load torque concerning a detector is displayed as it is There is no display digit CD 100M 10digit is 0 10 N m 1 0kgf cm 1 0lbf in CD 10M 10digit is 0 010 N m 0 10kgf cm 0 10lbf in 3 1 2 A setup and change in measurement mode Button to be used MODE Pushing the MODE button is continued for about 1 ...

Page 8: ...w if a bolt separates from a plinth it will race and it does not decompose and trouble is not caused to work However when it continues racing a ridge may be worn out and torque value may change Moreover by wear the metal fatigue etc of a screw where a spring is closed it is left and a bolt may jump out with the pressure New joint which served also as the measure against dangerous prevention in tha...

Page 9: ...urn off the power push an ON OFF button lightly for about 1 second If an AC DC adaptor is connected a display may be a full display but while the pilot lamp is on continue charge 3 5 About zero adjustment At the following this tester is performed zero adjustment automatically 1 When power is switched on 2 When measurement mode is changed When torque started during this movement it becomes impossib...

Page 10: ...for measurement it is also possible to remove the screw of the head of SJ joint and to measure as it is 4 1 2 The method of measurement 1 Install SJ joint in a torque detecting element SJ joint is fixable using the tapped hole for fixation of a detecting element nail portion 2 Press a power source key and switch on a power A power source is switched on after checking that load is not applied to a ...

Page 11: ...e a display is cleared and measurement is possible again 4 2 2 Measurement of Torque Wrench Although measurement of a torque wrench is also possible it restricts to the thing which is in measuring range and operates 1 Check whether measurement mode is PD peak down mode Measurement mode is changed into PD when PD is not displayed on display 3 1 2 references 2 Since 9 5 Hole is Open inside Torque De...

Page 12: ...for using a convenient function is set up PRG SET and and are used 1 Change in Setting Mode and Setup of Channel If it continues pressing the PRG SET key for about 1 second green LED GOOD lamp will stick the channel set up now is displayed The channel which wants to change a channel or the contents to use is set up by the UP key or the DOWN key ch1 ch4 When you change the channel to be used press ...

Page 13: ... 5 Setup of Real time Output Start Value After displaying a real time output start value is displayed A value is set up similarly When this value is set to 0 the inside of real time output mode continues outputting data If a setup is completed the PRG SET key will be pressed again 6 Auto Clear Setup After displaying a time of an auto clearance is displayed Time to carry out the zero clearance of t...

Page 14: ...lly point and tells you about at a lamp or a buzzer 1 Set up the maximum value and the minimum value used as a standard Reference 5 2 2 Measurement mode checks in PP Only measurement mode PP of a yes no decision is effective 3 When measured value is between a minimum and a maximum a GOOD lamp lights up When measured value is not between a minimum and a maximum NG lamp blinks and a buzzer sounds 4 ...

Page 15: ...ut A data output real time output mode can be carried out about 180 times in 1 second It can switch every 1 12 seconds The change method 6 5 Change of Output Speed of Data Reference 1 Set measurement mode as real time output mode Reference 3 1 2 2 If torque load becomes beyond the value set up beforehand the data output of the load torque will be carried out 3 If torque load becomes under a data o...

Page 16: ...ill move to measurement mode When memory data are eliminated individually 3 If the CLEAR key is pressed while displaying a memory number and a torque value on alternation it will blink 4 If the CLEAR key is again pressed during blink the data which displayed as and were chosen will be eliminated Subsequent data slide data to the eliminated portion 5 If it is left during blink it will be in the sta...

Page 17: ...aying it as last address choose the data number of the data of the last to output by or The MEM OUTPUT key will be pressed if selection finishes 5 Display it as and output After an output finishes it returns to a measurement state Press the CLEAR key for about 1 second to stop an output during an output 6 2 Output data Output data are outputted in the ASCII format with a USB cable In addition in o...

Page 18: ... Unit In N m etc the remainder is a space N m N m k g f c m kgf cm CR Carriage return cautions An interface cable is used for connection of a computer prepare a cable according to a computer Ask our company a cable 6 3 All Elimination of Saved Data 1 When carrying out package elimination of all the data it continues pushing until it displays the CLEAR key as About 4 seconds Push continuously and a...

Page 19: ...ontents of memory are eliminated Do not use it excluding the following condition When the display doesn t appear even if this machine is not used for a long term and charged Additionally when the tester doesn t work Since all the contents of memory are eliminated when system reset is performed redo a setup once again 8 Calibration Trust Service 8 1 Periodical calibration A regular proofreading is ...

Page 20: ...ime charge using the exclusive charger attached It does not display even if it switches on a power supply after charge of regulation time If it is not used over a long period of time an internal battery will carry out full electric discharge An AC DC adaptor is connected and a system reset button is pushed After a return push a clear button and give an indication zero It cannot measure When torque...