background image

7

IMPORTANT:

BEFORE STARTING THE EQUIPMENT,

READ THE CONTENTS OF THIS MANUAL, WHICH MUST
BE STORED IN A PLACE FAMILIAR TO ALL USERS FOR
THE ENTIRE OPERATIVE LIFE-SPAN OF THE MACHINE.
THIS EQUIPMENT MUST BE USED SOLELY FOR WELD-
ING OPERATIONS.

1  SAFETY PRECAUTIONS

WELDING AND ARC CUTTING CAN BE
HARMFUL TO YOURSELF AND OTHERS.
The user must therefore be educated

against the hazards, summarized below, deriving from weld-
ing operations. For more detailed information, order the
manual code 3.300.758

NOISE

This machine does not directly produce noise

exceeding 80dB. The plasma cutting/welding proce-
dure may produce noise levels beyond said limit;

users must therefore implement all precautions required by
law.

ELECTRIC AND MAGNETIC FIELDS - May be dangerous.

· Electric current following through any con-

ductor causes localized Electric and Magnetic
Fields (EMF). Welding/cutting current creates
EMF fields around cables and power sources.
· The magnetic fields created by high currents

may affect the operation of pacemakers. Wearers of vital
electronic equipment (pacemakers) shall consult their physi-
cian before beginning any arc welding, cutting, gouging or
spot welding operations.
· Exposure to EMF fields in welding/cutting may have other
health effects which are now not known.
· All operators should use the followingprocedures in
order to minimize exposure to EMF fields from the weld-
ing/cutting circuit:

- Route the electrode and work cables together - Secure

them with tape when possible.

- Never coil the electrode/torch lead around your body.
- Do not place your body between the electrode/torch 

lead and work cables. If the electrode/torch lead cable
is  on your right side, the work cable should also be on
your right side.

- Connect the work cable to the workpiece as close as 

possible to the area being welded/cut.

- Do not work next to welding/cutting power source.

EXPLOSIONS

· Do not weld in the vicinity of containers under pres-

sure, or in the presence of explosive dust, gases or
fumes. · All cylinders and pressure regulators used in

welding operations should be handled with care.

ELECTROMAGNETIC COMPATIBILITY
This machine is manufactured in compliance with the
instructions contained in the standard IEC 60974-10 (CL. A),

and must be used solely for professional purposes in an
industrial environment. There may be potential difficul-
ties in ensuring electromagnetic compatibility in non-
industrial environments.

DISPOSAL OF ELECTRICAL AND ELECTRONIC 
EQUIPMENT
Do not dispose of electrical equipment together
with normal waste!In observance of European

Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with
national law, electrical equipment that has reached the
end of its life must be collected separately and returned
to an environmentally compatible recycling facility. As the
owner of the equipment, you should get information on
approved collection systems from our local representa-
tive. By applying this European Directive you will improve
the environment and human health!

IN CASE OF MALFUNCTIONS, REQUEST ASSISTANCE
FROM QUALIFIED PERSONNEL.

1.1 WARNING LABEL

The following numbered text corresponds to the label
numbered boxes.

B.  Drive rolls can injure fingers. 
C.  Welding wire and drive parts are at welding voltage

during operation — keep hands and metal objects
away. 

Electric shock from welding electrode or wiring can
kill.

1.1 Wear dry insulating gloves. Do not touch electrode

with bare hand. Do not wear wet or damaged gloves. 

1.2 Protect yourself from electric shock by insulating

yourself from work and ground. 

INSTRUCTION MANUAL FOR WIRE WELDING MACHINE

Summary of Contents for EVO 160 M COMBI

Page 1: ...t side Connect the work cable to the workpiece as close as possible to the area being welded cut Do not work next to welding cutting power source EXPLOSIONS Do not weld in the vicinity of containers u...

Page 2: ...d address any complaints for losses or damage to the vector Please indicate the article and serial number whenever requesting infor mation about the welding machine 2 2 PLACEMENT Unpack the machine an...

Page 3: ...e used to com pletely disconnect the machine from the mains after S setting the switch 47 to O off The yellow green wire must be connected to the earth terminal Connect the earth clamp 37 to the part...

Page 4: ...elding PERALUMAN 5 magnesium wire For welding ERGAL 5 magnesium wire Use grinding wheels and brushes specifically designed for aluminium and never use them on other materials REMEMBER that cleanliness...

Page 5: ...ay Replace Increase gas delivery Thoroughly clean the edges with a metal brush Remove and clean or replace being careful not to clog the gas outlets replace Strictly avoid striking the torch or allowi...

Page 6: ...ERDE YELLOW GREEN V AZZURRO BLUE QUESTA PARTE DESTINATA ESCLUSIVAMENTE AL PERSONALE QUALIFICATO THIS PART IS INTENDED SOLELY FOR QUALIFIED PERSONNEL DIESER TEIL IST AUSSCHLIE LICH F R DAS FACHPERSONAL...

Page 7: ...61...

Page 8: ...62...

Page 9: ...PIANO INTERMEDIO INSIDE BAFFLE 18 CINGHIA BELT 19 APPOGGIO BOMBOLA GAS CYLINDER SUPPORT 20 RACCORDO FITTING 21 KIT SUPPORTO BOBINA COIL SUPPORT KIT 22 ELETTROVALVOLA SOLENOID VALVE 23 CAVO RETE POWER...

Page 10: ...64 CEBORA S p A Via Andrea Costa 24 40057 Cadriano di Granarolo Bologna Italy Tel 39 051 765 000 Fax 39 051 765 222 www cebora it e mail cebora cebora it...

Reviews: