background image

 2 CHANNELS BIESTABLE

RECEIVER VIA CABLE

TL-63

TECHNICAL CHARACTERISTICS

Voltage. ........................................................................... Through the booster.
Minimum Consumption. ................................................... 20 mA.
Maximum Consumption. .................................................. 120 mA.
Max Load per Output . ...................................................... 3 A.
Protection against polarity inversion, (P.I.P.). ................... Yes.
Dimensions. .......................................................................106 X 62 X 30 mm.

The TL-63will decode codes sent from the emitter, recognizing channels and connecting or disconnecting consequently 
outputs. It admits TL-50 and TL-51 transmitters . 
It includes micro switches to select the code, indicator leds, and connection terminals.

INSTALLATION

Note

. Before to start the installation, it is very important to carefully read the TL-55’s (booster) instruction manual, then you 

could use this module. 

POWER SUPPLY AND DATA ENTRY

. The TL-63 supply doesn’t require an external power supply. The module will be fed 

directly from the Receivers Communication Cable, provided by the booster, which also supply control data. For this 
connection do not use an independent cable from each receiver to the booster, but an union cable between your TL-61 and 
the Mmin Communication cable with Receivers. See Fig 1. 

.

Therefore, connect the positive and the negative cables of the power supply input and Data of the TL-61 to the respective positive and 
negative Communication Cable with Receivers. Before to follow the installation, make sure that the assembly has been correctly done.

www.cebek.com

    -    [email protected]

Summary of Contents for TL-63

Page 1: ... to carefully read the TL 55 s booster instruction manual then you could use this module POWER SUPPLY AND DATA ENTRY The TL 63 supply doesn t require an external power supply The module will be fed directly from the Receivers Communication Cable provided by the booster which also supply control data For this connection do not use an independent cable from each receiver to the booster but an union ...

Page 2: ...eceiver as it is described hereafter Select on each channel a decimal number between 1 and 255 When you indicate it on the corresponding micro switches battery you must do it in binary The conversion from a decimal number to a binary one or vice versa can be done with a scientific calculator See instructions of your calculator regarding this matter However you have a key with DEC decimal and BIN B...

Page 3: ...ng micro switches in each channel of the receiver as it is described hereafter 8 switches that can be placed in ON or OFF position compose each battery The first fours will allow the units adjustment whereas the last fours allowing the tens adjustment In order to introduce a number from 0 to 9 you have to do it in binary mode for units and tens See fig 5 Puts switches in ON or OFF positions accord...

Page 4: ...he number 8 Finally see fig 6 where you can find the final result OPERATING MODE Once the installation done and configured the TL 63 with its identification codes for each channel the module will be awaiting order from station Avoiding other codes when each channel receives its code for the first time it will activate the output remaining connected until the transmitter sends again its code and at...

Reviews: