CEA AQC06 Manual Download Page 1

MANUTENZIONE / MAINTENANCE

acido clorico e muriatico

cloric and muriatic acid

acido fluoridrico

hydrofluoric acid

sapone a PH neutro

neutral PH soap

NON UTILIZZARE

DO NOT USE

UTILIZZARE

TO USE

PH

7

NaClO

HFl

HCl

ipoclorito di sodio

chlorine bleach

ceadesign.it

Questi disegni sono proprietà di CEADESIGN SRL s.u. pertanto non potranno 

essere utilizzati e/o comunicati a terzi, anche in forma parziale, senza preventiva 

autorizzazione. CEADESIGN SRL s.u. si riserva il diritto di apportare modifiche ai 

disegni al fine di migliorare il prodotto.

CEADESIGN SRL s.u. has the property rights on these drawings, therefore they 

cannot be used and/or transferred to third party, even in partial form, without any 

prior authorization. Furthermore CEADESIGN SRL s.u. reserves the right to apply 

any change to these drawings in order to upgrade the product.

AQC06

_ REV11

G 1/2” 

G 1/2” 

G 1/2” 

400

(1’ - 3 3/4”)

MIN. 10 mm - MAX. 40 mm

(min. 25/64” - max. 1 37/64”)

MIN. Ø20 mm

(MIN. Ø25/32”)

2

(5/64”)

240

(9 29/64”)

255

(10 3/64”)

255

(10 3/64”)

550

(1’ - 9 21/32”)

240

(9 29/64”)

145

(5 45/64”)

170

(6 11/16”)

220

(8 21/32”)

360

(1’ - 2 11/64”)

MIN. 160 mm - MAX. 700 mm 

(min. 6 19/64” - max. 2’ - 3 9/16”)

130

(5 1/8”)

LED CONTROL UNIT

CENTRALINA

INPUT: 100 - 220VAC 50/60HZ

OUTPUT: 12V

Una centralina di controllo 
gestisce un solo soffione /  

Each LED control unit operates 
only one shower head

90

(3 35/64”)

60

(2 23/64”)

L. 5000 mm (5 m)

(L. 16’ - 4 27/32”)

L. 5000 mm (5 m)

(L. 16’ - 4 27/32”)

HOME AUTOMATION 

SYSTEMS

SISTEMI DI DOMOTICA

OR

(ART.CODE BOT02)

PUSH POWER BUTTON

INTERRUTTORE ON/OFF

PRODOTTI CORRELATI / RELATED PRODUCTS

BOT02

CEA DESIGN STUDIO

AQC06/FREE IDEAS

AISI 316/L STAINLESS STEEL

Soffione ad incasso con getto a pioggia, getto nebulizzato, getto 
a cascata, LED cromoterapia e ugelli in silicone, completo di 
centralina di controllo. Da abbinare ad interruttore On/Off BOT02

Built-in shower head with rain, mist, waterfall jets, LED 
chromotherapy and silicone nozzles. LED control unit included 
to combine with push power button BOT02

Prodotto che necessita di collegamento elettrico

Product that needs electrical connection

Summary of Contents for AQC06

Page 1: ...25 64 max 1 37 64 MIN 20 mm MIN 25 32 2 5 64 240 9 29 64 255 10 3 64 255 10 3 64 550 1 9 21 32 240 9 29 64 145 5 45 64 170 6 11 16 220 8 21 32 360 1 2 11 64 MIN 160 mm MAX 700 mm min 6 19 64 max 2 3 9...

Page 2: ...ra de la persona La representaci n es indicativa AVERTISSEMENTS D INSTALLATION La hauteur optimale de l emplacement du produit est d terminer selon la taille de la personne La repr sentation est purem...

Page 3: ...me a la altura de la persona La representaci n es indicativa AVERTISSEMENTS D INSTALLATION La hauteur optimale de l emplacement du produit est d terminer selon la taille de la personne La repr sentati...

Page 4: ...er illuminazione inclusa Built in shower head with rain mist waterfall jets LED chromotherapy and silicone nozzles LED control unit included INDICE INDEX 9 5 6 8 FUNZIONAMENTO LED LED OPERATION INSTAL...

Page 5: ...rope EN 60598 1 2 Germany VDE 100 Teil 701 Austria VE EN 1 Teil 4 49 Switzerland NIN 100 France NF C 15 100 section 7 701 Luxembourg EVU VDE 100 Teil 701 Great Britain BS 7671 Netherlands NEN 1010 727...

Page 6: ...ection 7 701 Luxembourg EVU VDE 100 Teil 701 Great Britain BS 7671 Netherlands NEN 1010 727 1 2 Belgium R G I E Art 86 10 Italy CEI 64 8 7 sez 701 1 L interruttore On Off BOT02 deve essere posizionato...

Page 7: ...ancione rosso viola rosa blu With the device turned on press the push power button tBOT02 wice to go from one color to another blue light blue green orange red violet pink blue ON luce fissa ON fixed...

Page 8: ...legata prima ai LED del soffione e solo successivamente alla rete elettrica 2 L impianto deve essere eseguito da tecnici qualificati e conformemente alle norme vigenti 1 The electronic control unit mu...

Page 9: ...The pipes have to be rinsed thoroughly before installation TECHNICAL WARNINGS AVVERTENZE TECNICHE AQC06_ REV11 MIX WATER SUPPLY DN15 G1 2 Miscelatore Mixer A A B X Y X 510 mm 1 8 5 64 Y 310 mm 1 13 64...

Page 10: ...ceadesign it AQC06_ REV11 A A 6 x4 400 mm A B C D A B 6 7 5 8 10...

Page 11: ...ceadesign it AQC06_ REV11 A C B B A D C C B A B A 10 11 9 12 11...

Page 12: ...pressure 5 bar in caso di pressioni statiche superiori a 5 bar si raccomanda l installazione di un riduttore di pressione per evitare danni al prodotto Use of a pressure reducer when static pressure i...

Page 13: ...e richieste siano compatibili con l apparecchio L utilizzo di alimentatori con caratteristiche diverse o incompatibili possono danneggiare irreparabilmente il prodotto e far decadere la garanzia PRODO...

Page 14: ...ications are compatible with the equipment provided Using a feeder of different or incompatible specifications can irreparably damage the equipment and invalidate the guarantee CLASS 2 LASER PRODUCT C...

Reviews: