EN
EN
10
IFACE™
ievo iface™ Facial Recognition Terminal
Installation Procedure
Wall mount
You can install the device onto a wall directly by using the mounting plate.
1. Remove the screw that attaches iface
TM
to
the mounting plate and disassemble the
plate.
Keep the screw because it will be used to
attach them together again.
For
concrete walls
, follow these steps:
1. Put marks on the wall through the plate’s
screw holes by using a marker.
2. Drill the marked points by using an
electric drill.
3. Attach the anchor bolts to the holes by
using a hammer.
4. Attach the plate to the wall with the
screws.
1. Put the mounting plate at the pre-
determined position and attach the plate
onto the wall with the screws (M4 x 8 min).
2.
1. Connect the power cable and peripheral
cables, if necessary, to the connectors in
the rear panel. (See Connecting Cables for
more information)
3.
1. Note:
Step to be included only for conduit
mounting.
4.
1. Put the device onto the installed plate,
slide it downward, and attach it with the
screw (M3 x 6)
5.
Wall mounting points
Remove one or more plastic tabs to allow
the wire routing and let the cables go
through the openings.