background image

Manufacturing Access Control since 1985

I300ER 

300Kg Mortice Electromagnetic lock

EN

PACKAGE CONTENT

Magnetic 

lock

Armature 

plate

5x16

Roll pin

M5X8

Srew

Steel washer

Rubber 

washer

11

11

22

88

22

11

M8x35

Screw

M8x25

Screw

Cap nut

Joggle 

bracket

Manual

11

11

11

22

11

PRODUCT PRESENTATION

 Monitored

 Mortice

 High corrosion resistance

 Delivered with armature plate

 No mechanical wear

 Ease of installation

 Recommended for exterior use

 Fail safe (Door unlocked when power off)

 Holding force : 300 kg

  Built-in varistor :  Built-in electronic protection to  

eliminate back EMF

 Dimensions (L x W x D): 228 x 38 x 27mm

 Armature plate dimensions (L x W x D): 185 x 38 x 11mm

 Power supply: 12/24V dc

 Consumption:   480 mA with 12V dc 

240 mA with 24V dc 

CE Certification

WEEE & RoHS

IP42

Armature plate support 

AMB300  (optional)  

Armature plate 

Armature plate 

Roll pin 

Roll pin 

Steel washer

Steel washer

Screw

Screw

Screw

Screw

Rubber washer

Rubber washer

Armature plate screw

Armature plate screw

Screw

Screw

Screw

Screw

Joggle bracket

Joggle bracket

Joggle bracket

Joggle bracket

MOUNTING RECOMMENDATIONS

OPTIONAL ACCESSORIES

References

AMB300

Description

Description

Armature mounting 

Armature mounting 

plate

plate

Armature plate 

-  It is vital that the magnetic lock and armature 

plate are securely fixed to their supports.

-  The magnetic lock and the armature plate must 

be aligned.

-  The armature plate must be mounted “floating” 

around the central mounting screw to 

compensate for any misalignment of the door

Stainless steel

CDVI_I300ER_IM_01_EN-FR_A4_B - G0301FR1059V01

CDVI 

EXPORT

31, av. du Général Leclerc

93500 PANTIN - France

Phone +33 (0)1 48 91 01 02

www.cdvi.com

CDVI

 SWEDEN 

[SWEDEN - DENMARK - 

NORWAY FINLAND]

Phone +46 (0)31 760 19 30

www.cdvi.se

CDVI

 UK 

[UNITED KINGDOM - IRE-

LAND]

Phone +44 (0)1628 531300 

www.cdvi.co.uk

CDVI

 AMERICAS

[CANADA - USA]

Phone +1 (450) 682 7945

www.cdvi.ca

CDVI

 BENELUX

[BELGIUM - NETHERLAND - 

 LUXEMBOURG]

Phone +32 (0) 56 73 93 00

www.cdvibenelux.com

CDVI

 SUISSE

Phone +41 (0)21 882 18 41

www.cdvi.ch

CDVI

 IBÉRICA

[SPAIN - PORTUGAL]

Phone +34 (0)935 390 966

www.cdviberica.com

CDVI

 ITALIA

Phone +39 0321 90 573 

Fax: +39 0321 90 8018

www.cdvi.it

CDVI 

TAIWAN

Phone +886 (0)42471 2188

www.cdvichina.cn

CDVI

 CHINA 

Phone +86 (0)10 

84606132/82

www.cdvichina.cn

CDVI

 MAROC

Phone +212 (0)5 22 48 

09 40

www.cdvi.ma 

CDVI 

POLSKA

Phone +48 12 659 23 44

www.cdvi.com

Do not connect the magnetic 

lock without the PCB.

10

WARRANTY

YEAR

ELECTRICAL CONNECTIONS

Voltage selection jumpers

Recommended power supplies

12V dc default setup

The N.O./N.C. signal only switches when the door is 

closed with the electromagnetic lock powered

Check the jumper position before connecting the 

lock to the input current. A wrong position could 

damage  the  lock.  This  type  of  damage  is  not 

covered by the warranty.

IMPORTANT NOTE

Terminal

block

Correspondence

+

12 or 24V dc

-

- 0 V

NC

Normally closed

C

COM

NO

Normally open

ADC335

12V dc

ADC612S

24V dc

Reviews: