Edition 12/2005

Terminal

Description

B

Request-to-Exit input 1

E

Request-to-Exit input 2

M

Common REX inputs

R

N/C Contact door

C

Common

T

N/O Contact door

V1,V2

Varistor

ST1

Jumper for reset

S,S

Tamper Switch output

N

O

T

I

C

E

 

 

D

E

 

M

O

N

T

A

G

E

 

E

T

 

D

U

T

I

L

I

S

A

T

I

O

N

This device comes with a varistor.

The varistor must be connected to the strike terminal

(electromagnet…) operated by the device.

If this product works with many strikes, each of them

should have a varistor.

The varistor controls the overload produced by the strike
coil – self-effect.

If you are using a « Shear Lock » electromagnetic lock, it is recommended to

use a separate power supply than the one connected to the

DG502U

!

Warning

Do not use a switching power

supply because of the interference

radiation that may disturb the

reading of the badges

Ne pas utiliser d’alimentation

à découpage à cause de

rayonnements parasites pouvant

perturber la lecture des badges.

PB1

PB2

C

R

T R C T S S B M E 1 2 3 4 5 6 12 V 12

1

2

3

4

5

6

7

8

9

0

#

RL1

RL2

12 3

ST1

V1

strike

Input voltage

12VAC/DC

V

M

A

G

N

E

T

V2

DG502U/A

DG502U/P

2-DOOR CONTROLLER

500 USERS

Summary of Contents for DG502U/A

Page 1: ...hould have a varistor The varistor controls the overload produced by the strike coil self effect If you are using a Shear Lock electromagnetic lock it is recommended to use a separate power supply tha...

Page 2: ...nly 160mA DG502 with 1 remote reader 240mA DG502 with 2 remote readers 320mA Audible Feedback 1 long beep Validation of data in programming mode master code proximity badge or time delay Or access cod...

Page 3: ...off during 1 second and an audible beep indicates the validation of the enrolment reader In stand by mode if the enrolment reader is the controller built in reader all the readers can be used but if t...

Page 4: ...lue is 12345 2 beeps and the orange LED lights on to confirm that you have entered into the programming mode 2 Enter 4 and then select the access level 01 or 02 or 03 one beep is emitted 3 Enter the u...

Page 5: ...r on the DG502 the LED is still off Remove the jumper from ST1 2 3 position the LED flashes orange Wiring of the Remote Readers Follow the schematic on page 1 to connect remote reader 1 to the control...

Page 6: ...Edition 12 2005 6 Template 13mm 8 mm 3 x 6 mm 25 mm 116 mm 85 mm 22mm 116 mm 61 5m mmm 99 mm 75 mm DG 502 Remote Reader...

Page 7: ...12 V DG502 It is possible to use a separate power supply for the remote reader It is recommended to keep a distance of 60 CM minimum between the DG502U Controller and a remote reader between 2 remote...

Page 8: ...2 3 4 5 6 12 V 12 V DG502 DISTANCE 60 cm minimum 50 meters maximum Back view remote reader It is possible to use a separate power supply for the remote reader DG502 remote reader 2 DG502 controller R...