Manufacturing Access Control since 1985
Surface
mount
magnet
Armature
plate
Mounting
plate
Roll pin
5x16
Steel
washer
Rubber
washer
M8x35
screw
Cap
nut
Wood
screw
4x25
installation
Manual
1
1
1
2
2
1
1
2
8
1
C3S11
300 Kg Surface Mount Electromagnetic lock
EN
PRODUCT PRESENTATION
INSTALLATION
PACKAGE CONTAIN
- NFS 61-937.
- Monitored.
- Surface mount.
- Delivered with armature plate.
- Corrosion resistance.
- No mechanical wear.
- Ease of installation.
- Recommended for interior use.
-
Fail safe (Door unlocked when power off).
- Holding force:
300kg.
- No residual magnetism.
- Built-in varistor:
Built-in electronic
protection to eliminate back EMF.
- 10 year warranty.
- Dimensions (L x W x D): 250 x 43 x 27mm.
- Armature dimensions (L x W x D): 185 x 38 x 11mm.
- Power supply: 12/24V dc.
- Power absorption:
- 12 V DC = 480mA,
- 24 V DC = 240mA.
ADC335
BS602
Recommended
power supplies
EC certification
WEEE & RoHS
IP42
Electromagnetic lock
M8
screw
Rubber washer
Roll pin
Steel washer
Cap nut
G0301FR0337V05
All the information contained within this document (photos, drawing, features, specifications and dimensions) could be perceptibly different and can be changed without prior notice. cdvi.com
ELECTRICAL CONNECTIONS
The NO/NC signal only switches when
the door is closed with the power to it on.
12V dc Default setup
Terminal
block
Correspondence
+
12 or 24V dc
-
- 0 V
N.C
NC (Normally closed)
COM
COM
N.O
NO (Normally open)
WITH BUILT-IN PCB BOARD
- Check the jumper position before connecting
the lock to the input current. A wrong position
could damage the lock. This type of damage
is not covered by the warranty.
- Make sure that the magnet and the armature
meet evenly over their entire mating surfaces.
The Armature plate must be able to pivot
slightly about its center mounting screw
to compensate for any door misalignment.
IMPORTANT NOTE
12V dc
24V dc
Voltage selection
jumpers
Cap nut
Armature