CDN DTTW572 Quick User Manual Download Page 1

Model: DTTW572

 

WATERPROOF THIN TIP THERMOMETER

-40 to +572°F/-40 to +300°C

FOR THIN CUTS OF MEAT AND 

GENERAL PURPOSE COOKING

 NSF

®

 Certified

  4 second response

  1.5 mm thin tip

  3.5"/8.9 cm stem

  Waterproof (IPX7: protected from water up to  

3 feet/1 meter for 30 minutes)

  Field calibration

  High heat

 Max/min

 Data-hold

  Big digit

  180° rotating display

  On/off button

  Auto-off after 10 minutes

  Food-safe ABS plastic with BioCote

®

  304 stainless steel stem

  Temperature guide on thermometer

  2-way mounting: pocket clip/hook

  Two 1.5V IEC LR44 button alkaline batteries (included)

Note: 

Remove label from display before initial use.  

Clean the thermometer stem before each use.

Note:

 In the following instructions, names of the control 

buttons are shown in CAPS. Function information that 

appears on the display is shown in 

BOLD CAPS

.

BATTERY INSTALLATION

Replace batteries when LCD becomes dim.  

---

” flashes on the display when the batteries need 

to be replaced.
1.  Power off the unit before installing the batteries. 

A malfunction may occur if the power is on when 
the batteries are installed. If a malfunction occurs, 
restart the device.

2. Using a small Phillips screwdriver, remove the 

screw on the back by the pocket clip by turning it 
counter clockwise. 

Note:

 Be careful to use a properly-sized screwdriver as a 

screwdriver too large will strip the screwtops.

3. Remove the cover completely.
4. Install two LR44 batteries with positive (+) sides up. 
5. Replace the battery cover. 

Important: THE WATER RESISTANT FEATURE REQUIRES 

MAINTAINING THE RUBBER GASKET EVENLY WITHIN THE 

GROOVE.

6. Fasten the screw on the back by turning it 

clockwise, being careful not to over-turn.

OPERATING INSTRUCTIONS

A. On/Off

1.  Press the POWER button ( ) to turn the 

thermometer on.

2. The DTTW572 will automatically turn off after  

10 minutes of inactivity.

3. Press the POWER button ( ) again to turn  

the thermometer off and conserve battery life.

B. Temperature Scale 

To select temperature reading in Fahrenheit  
or Celsius:
1.  Using a paperclip, press the °F/°C button  

on the back to change the scale.

2. The 

°F

 or 

°C

 symbol changes on the display.

C. Display Rotation 

While the DTTW572 is on, press and hold the 
MAX/MIN button to rotate the display orientation 
180 degrees. 

Note:

 Pressing and holding the MAX/MIN  

button in the Max or Min mode will clear  

the values.

Tel

 800 338-5594  

Fax

 800 879-2364  

Web

 CDNmeasurement.com

Reviews: