CDI 5400
FLOWMETER FOR COMPRESSED-AIR SYSTEMS - Rev. 3
• Easy to install
• Display rotates to facilitate use on horizontal
or vertical pipes
• No moving parts
• Weather resistant and surge protected
• Milliamp output
• Pulse output convertible to threshold output
• User-configurable scaling, filtering and units
of measure
• Optional wired and wireless outputs for networking
The CDI 5400 clamps onto a pipe, with two flow-sensing probes
projecting into the pipe through 3/16-in. drilled holes. It seals
directly to the pipe; no cutting or welding is required for installa-
tion. Because each flowmeter is made and calibrated for a
specific size of pipe, the digital display indicates flow directly,
with no setup or adjustment.
The meter measures flow by maintaining one probe warmer
than the other. It determines the mass flow rate from the amount
of heat required. The flow rate, in scfm or equivalent units, is
shown on a large, four-digit display; a 4-20 mA output and a
pulse output permit remote dis-play, totalizing and data collection.
AVAILABLE SIZES
CDI METERS, INC.
10/24/2016
© CDI Meters, Inc. 2016
Specifications are subject to change without notice.
SPECIFICATIONS
Accuracy
5 percent of reading plus 1 percent of range for flows from
10 percent to 100 percent of indicated range at air tempera-
tures between 20 and 120 degrees Fahrenheit
Fluids
Compressed Air, Nitrogen
Operating Pressure
200 psig maximum on Sch. 40 steel and on Type L Copper;
consult CDI for other materials and higher pressures.
Input Power
250 mA at 24 Vdc
Output resistance
600 Ohms max.
Exposed Materials
Stainless steel, gold, thermal epoxy and Viton (seal)
Display
Four-digit LED display
Response time
One second to 63 percent of change in value at flows above
30 percent of range
US Patent 6,802,217
Nominal
Size
a
Range
b
(scfm)
Model No. for
Sch 40 Steel
Model No. for
Type L Copper
2 in.
600
5400-20S
5400-20C
2.5 in.
800
5400-25S
5400-25C
3 in.
1200
5400-30S
5400-30C
b
4 in.
2000
5400-40S
5400-40C
5 in.
2500
5400-50S
—
6 in.
5000
5400-60S
—
8 in
6000
5400-80S
—
(a) Other sizes are available. Please contact CDI. For metering larger
pipe sizes, please see our 5400 Series flowmeters.
(b) Range of milliamp output and recommended maximum flow. Flowmeters
for copper pipe have smaller ranges. Meters will function at somewhat
higher flow rates but at reduced accuracy.