25
Figure 19
Figure 20
J
J
Conversion to Natural Gas or LPG
REPLACING THE BURNER INJECTORS
If the NATURAL GAS/LPG conversion kit is not supplied with the appliance this kit can
be purchased by contacting the After-Sales Service.
Choose the injectors to be replaced according to the table on next page.
The injector diameter, expressed in hundredths of a millimetre, is marked on the
injector body.
To replace the injectors proceed as follows:
✓
Remove the gratings, the burner covers and the knobs;
✓
Using a wrench, substitute the nozzle injectors “
J
” (Figs. 19 - 20) with those most
suitable for the kind of gas for which it is to be used.
The burners are made in such a way so as not to require regulation of the
primary air.