background image

Customer Care Department  •  The

 

 

Group Ltd.  •  Harby Road  •  Langar  •  Nottinghamshire  •  NG13 9HY

T :

 01949 862 012   

F :

 01949 862 003   

E :

 [email protected]   

W :

 www.cda.eu

www.cda.eu

3U10 Extractor

Installation, Use and Maintenance

Summary of Contents for 3U10

Page 1: ...omer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E customer care cda eu W www cda eu www cda eu 3U10 Extractor Installation Use and Mainten...

Page 2: ...pervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenance except by...

Page 3: ...he need to dispose of household appliances separately the product is marked with a crossed out wheeled dustbin Please note Under no circumstances should the extractor be connected to any gas ventilati...

Page 4: ...actors such as supply voltage and cleanliness of the filters Note For best performance you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 mi...

Page 5: ...f this key To decrease the speed touch the Minus key B The speed will decrease by one increment for each touch of this key Energy saving functions To help save energy After 5 minutes of running at the...

Page 6: ...ANT DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY Cleaning You should use a nonabrasive cleaner Any abrasive cleaner including Cif will scr...

Page 7: ...el to the right to release its upper locating tabs in their slots Fig 2 Carefully lower the filter panel from the extractor The grease filters may be removed from the filter panel for cleaning by firs...

Page 8: ...RTANT Steam cleaners must not be used to clean this appliance If your extractor is not working 1 Check that the mains supply has not been switched off 2 Check that the fuse in the spur has not blown I...

Page 9: ...dance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the t...

Page 10: ...you must be able to isolate the extractor from the mains electrical supply after installation This appliance is intended to be connected to the mains electrical supply by means of an isolation switch...

Page 11: ...legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported to RIDDOR The height should be measured from the top of the burners IN THE ABSENCE...

Page 12: ...able drill for the type of wall Two holes for the top hanging brackets Two holes toward the bottom for the lower angle brackets Note The size required for the holes is dependent on the wall fixings to...

Page 13: ...sition 6 Lift the extractor body into position and hang it with the key hole slots in the upper hanging brackets over the upper wall screws 7 Insert screws through the lower fixing brackets to secure...

Page 14: ...lation no chimney section is used 1 Fit the mesh cover into the air outlet this simply drops into position Fig 9 2 Ensure that charcoal filters are fitted as described in the Care and Maintenance sect...

Page 15: ...rs for both round and rectangular ducting are included with the chimney 3 Fit your choice of ducting to the outlet and route it through the ceiling or wall as required 4 Make any necessary electrical...

Page 16: ...16 Notes...

Page 17: ...17 Notes...

Page 18: ...18 Notes...

Page 19: ...77 4 Measured airflow at Best Efficiency Point QBEP 263 7 m 3 h Measured Pressure at Best Efficiency Point PBEP 141 Pa Maximum airflow QMAX 495 9 m 3 h Measured electric power at Best Efficiency Poin...

Page 20: ...F 01949 862 003 E customer care cda eu W www cda eu www cda eu Please contact our Customer Care Department for Service on the details below Customer Care Department The Group Ltd Harby Road Langar No...