background image

CCTV  tester  PRO

 

User

s  Manual

 

                     

Page.12

 

7. Address search 

Search the ID of PTZ camera

 

 

8. Digital Multimeter 

Digital  Multimeter  performs  AD/DC  Voltage,  AC/DC  Current, 

Resistance,  Continuity,  Capacitance  and  Diode  test ,  Auto  /   

Manual Range, Data hold, Relative measuring. 

 

3.3  PTZ Controller 

Display  the  input  video  images.  Pan/tilt  the  P/T  unit  and  zoom  in/  out  the  image.  Setup  the 

controlling parameters like protocol, communication port, baud rate, PTZ ID, pan/tilt speed; set 

and call preset position. 

 

The following connections should be confirmed before use 

a. The Video In interface of the CCTV testerPRO and the output interface of camera 

b. Data A+ of the CCTV testerPRO and A+ of the PTZ camera or controlling device, data B- of 

the instrument and B- of the PTZ camera or controlling device 

 

Note:    Don’t connect communications interface with a circuit  the voltage higher than 6V. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Tester Pro

Page 1: ...USER S MANUAL CCTV Tester Pro ...

Page 2: ...afely please first read the Safety Information carefully in the manual The manual should be kept well in case of reference Keep the S N label for after sale service within warranty period Product without S N label will be charged for repair service If there is any question or problem while using the CCTV testerPRO or damages occurred on the product please contact our technical Department ...

Page 3: ... 5 Installing the Battery 9 3 Operation 10 3 1 Power on off 10 3 2 Menu Functions 10 3 3 PTZ controller 12 3 4 Video setting 15 3 5 Colorbar generator 16 3 6 Cable tester 16 3 7 Data monitor 17 3 8 Device setting 17 3 9 Address search 18 3 10 Digital multimeter 19 4 DC12V Power output 26 5 Audio input test 26 6 Specifications 27 6 1 General specifications 27 6 2 Multimeter specifications 28 ...

Page 4: ...chnician of our company The instrument should not be used under the environment with strong electromagnetic interference Don t touch the tester with wet hands or waterish things Don t use the detergent to clean and the dry cloth is suggested to use If the dirt is not easy to remove the soft cloth with water or neutral detergent can be used but the cloth should be tweaked sufficiently About digital...

Page 5: ...g diode testing PTZ control Pan tilts the P T unit zooms in out the lens adjusts the focus aperture and sets and calls the preset position PTZ continuing rotate test Video displaying Automatically adapts and displays the video format of NTSC PAL LCD Brightness Contrast Color Saturation are adjustable Video Generating The PAL NTSC multi system colorbar video generator seven system switchable transm...

Page 6: ...n It can last 12 hours for normal use after charging for 4 hours 2 2 CCTV testerPRO Kits Professional design light and portability video display and data control are deliberately integrated which makes the instrument so simple practicable easy for use that the training is almost unnecessary for an operator to be skillful 1 CCTV testerPRO 3 LAN Cable Tester 5 BNC Cable 6 Safety cord 7 RS485 data ca...

Page 7: ...ed 3 The data transmission indicator it lights red while the data is being transmitted 4 The charge indicator it lights red while the battery is being charged As the charging is complete the indicator turns off automatically 5 The display Icon of battery electricity it displays the electric quantity 6 Main menu it shows main functions of CCTV testerPRO 7 Sub menu Shows and sets the values of funct...

Page 8: ...Leftward Enter the sub menu or select the parameter whose value will be changed Reduce the value of the parameter Pan the PTZ left 13 Rightward Enter the sub menu or select the parameter whose value will be changed Add the value of the parameter Pan the PTZ right 14 Downward Select the item which will be set or reduce the value of the parameter Tilt the PTZ downward 15 Confirm Open Confirm the set...

Page 9: ...Please use together with UTP LAN cable tester 25 RS232 interface RS232 communication for the PTZ 26 Audio input test the pickup and other audio equipments on the front end 27 DC12V1A power output output DC12V power for camera 28 Tester speaker 29 Video input BNC input interface Inputs the video 30 Video output BNC output interface Outputs the video 31 RS485 422 Interface RS485 RS422 communication ...

Page 10: ... At the first time of use the batteries should be completely exhausted and then recharged for 4 or 5 hours The Charge Indicator lights red when charging the battery The charge indicator turns off automatically when the charging is completed Notice When the Charge Indicator turns off the battery is approximately 90 charged The charging time can be extended for about 1 hour and the charging time wit...

Page 11: ... settings Colorbar generator LAN cable tester Data monitors Device setting and enter corresponding function setting sub menu Press SET key to set the parameters in function sub menu Note When the CCTV testerPRO is powered on it will return to the function which is being operated before it is turned off 1 PTZ controller Display the input video images Pan tilt the P T unit and zoom in out the image ...

Page 12: ...other equipment 4 Cable tester Test LAN cable or telephone cable The connecting condition and the sequence of wires will be displayed as well as the serial number of the cable tester kit 5 Data Monitor Captures the protocol from the controlling system and display command data It is helpful to debug and maintain RS485 communication 6 Device setting Set the parameters of the CCTV testerPRO Auto powe...

Page 13: ...t and zoom in out the image Setup the controlling parameters like protocol communication port baud rate PTZ ID pan tilt speed set and call preset position The following connections should be confirmed before use a The Video In interface of the CCTV testerPRO and the output interface of camera b Data A of the CCTV testerPRO and A of the PTZ camera or controlling device data B of the instrument and ...

Page 14: ...cording the ID of PTZ camera 0 254 BOSCHOSRD 1 16384 Press or to adjust address press or for step 100 adjustment E Pan Speed Set the pan speed of PTZ camera 0 63 F TiltSpeed Set the tilt speed of PTZ camera 0 63 G Set PS Setup preset position 0 128 a P T Z the camera to desired position b Press SET key to enter PTZ controller submenu c Move the yellow cursor to Set PS and then press or key to sele...

Page 15: ...l OSD menu of the PTZ controller OSD Menu of Dome For reference only MAIN MENU 1 DISPLAY SETUP 2 CAMERA SETUP 3 CONTROL SETUP 4 CAMERA MASK SET 5 PROGRAM 6 PAL CAMERA 7 CAM DEFAULT SET 8 DOME RESET 9 EXIT MAIN MENU 1 Display configuration 2 Set camera parameters 3 Set PTZ controlling 4 Set privacy mask 5 Set auto running functions 6 PAL NTSC Switch 7 Restore the default settings 8 Reset the dome 9...

Page 16: ...otating smoothly or get stuck The install worker could judge whether the PTZ has problem by observing the PTZ 3 4 Video Setting User can customize the brightness contrast and saturation of the LCD according to the using environment the CCTV tester auto display the format PAL NTSC of video input and analysis the input video signal level a Press the or key to select the parameter which we want to ch...

Page 17: ... testerPRO will display Normal when video levels are 1000mV 20 Exceed or Weak will be displayed when video level out of 1000mV 20 3 5 Colorbar generator Output video at any mode Output or receive seven different forms of video color bar to test monitor video cable or other equipment a Press the or key to select the parameter which we want to change the value b Press the or key to change the value ...

Page 18: ...ey to select communication port according to the system connection Press SET key to save the change d Press or key to select the baud rate according to the baud rate of controlling system and then press SET key to save the change and capture command data from controlling system e Press RETURN key to clear the screen 3 8 Device setting Set the parameters of the CCTV testerPRO Auto poweroff Setting ...

Page 19: ...enu Press key to confirm after change Address search to on which add address scan sub menu Press to switch the sub menu as illustrated Note The system returns to OFF after shutdown and the scan sub menu closes automatically Set ON again for next use Press key to set protocol communication port communication rate make them same as the PTZ camera Press or key the address values is constantly on the ...

Page 20: ...ecreasing button the tester will search up the ID step by step from 256 to 1 When the ID is searched the PTZ camera will stop panning Press button the tester will search up the ID quickly and continuously from 256 to 1 When the ID is searched the PTZ camera will pan left At this time please press any key to stop searching up Press manual single step incremental button the tester will search up the...

Page 21: ... range 00 00V 66V range 000 0V 660V range 000 0mV 660mV range c Connect test leads across the source or load under measurement d You can get reading from LCD The polarity of the red lead connection will be indicated along with the voltage value NOTE When only the figure OL is displayed it indicates over range situation and the higher range has to be selected When the value scale to be measured is ...

Page 22: ...icates over range situation and the higher range has to be selected When the value scale to be measured is unknown beforehand set the range selector at the highest position C DC Current Measuring a Connect the black test lead to the COM jack and the red test lead to the mA jack for a maximum of 660mA current For a maximum of 10A move the red lead to the 10A jack WARNING You can t input the voltage...

Page 23: ...o be selected When the value scale to be measured is unknown beforehand set the range selector at the highest position The maximum current of mA socket is 660mA over current will destroy the fuse and will damage the meter The maximum current of 10A socket is 10A over current will destroy the meter and will damage the operator D AC Current Measuring a Connect the black test lead to the COM jack and...

Page 24: ...rrent of mA socket is 660mA over current will destroy the fuse and will damage the meter The maximum current of 10A socket is 10A over current will destroy the meter and will damage the operator E Resistance Measuring a Connect the black test lead to the COM jack and the red test lead to theΩ jack b Press to selectΩ enter theΩ measurement Auto range by press key and Manual range by press Manual ra...

Page 25: ...leads across two point of the circuit under testing d If continuity exists i e resistance less than about 50Ω built in buzzer will sound e You can get reading from LCD NOTE If input open circuit or the circuit resistance measured is higher than 660Ω then the figure OL will be display G Diode Testing a Connect the black test lead to the COM jack and the red test lead to the jack b Press to select e...

Page 26: ... capacitance measurement Auto range by press key and Manual range by press Manual range 0 000nF 6 6nF range 00 00nF 66nF range 000 0nF 660nF range 0 000uF 6 6μF range 00 00uF 66μF range 000 0uF 660μF range 0 000mF 6 6mF range 00 00mF 66mF range c Before connect test leads across two sides of the capacitor under measurement be sure that the capacitor has been discharged fully d You can get reading ...

Page 27: ...CCTV tester to avoid destroy b Don t output this DC12V 1A power to the power input port of the CCTV tester to avoid destroy c When the requirement of the camera is higher than 1A the CCTV tester will enter protection mode Disconnect all the connections of the CCTV tester and then connect the CCTV tester with power adaptor to resume the CCTV tester 5 Audio input test Test the audio input from picku...

Page 28: ... etc Baud Rate 150 300 600 1200 2400 4800 9600 19200bps Video Signal Generation Color bar generation Output one channel PAL NTSC colorbar video signal for testing monitor or video cable Digital multimeter Multimeter Voltage current resistance and capacitance measuring continuity testing diode testing UTP CABLE TEST UTP cable test Test UTP cable connection status and display in the screen Read the ...

Page 29: ... Weight 176mmx94mmx36mm 340g 6 2 Multimeter specifications Counts 6600 6600 Conversion rate 3 times s Current modes for clamp meter with ZERO function DC Voltage Range Accuracy Resolution 660mV Manual range 0 3 4 0 1mV 6 6V 1mV 66V 10mV 660V 100mV AC Voltage Range Accurac Resolution 660mV Manual range 1 5 6 0 1mV 6 6V 0 8 6 1mV 66V 10mV 660V 100mV DC Current Range Accurac Resolution 6 6mA 0 5 3 1u...

Page 30: ...6mA 10uA 660mA 100uA 10A 1 5 10mA Resistance Range Accurac Resolution 660Ω 0 8 5 0 1Ω 6 6KΩ 0 8 2 1Ω 66KΩ 10Ω 660KΩ 100Ω 6 6MΩ 1KΩ 66MΩ 1 2 5 10KΩ Continuity Range Function Built in buzzer will sound if resistance is lower than 50 Ω Diode Range Resolution Function 1mV Display read approximate forward voltage ofdiode ...

Page 31: ... 3 5 8 10pF 660nF 100pF 6 6μF 1nF 66μF 10nF 660μF 5 8 100nF 6 6mF 1μF 66mF 10μF The data above is only for reference and any change of them will not be informed in advance For more detailed technical inquiries please feel free to call the Technical Department of our company Products certification ...

Reviews: