background image

                            U s i n g   M o d e l s   w i t h   a n   A C   I n p u t

Name and Function of Each Part

1

Wire Connection

3

Do not bundle the cables with high-voltage lines or power lines. Doing so may cause the 

Control Unit to malfunction.  Keep the cables as far away from such lines as possible.

Caution

Make sure that the power source is turned OFF, and then connect the Control Unit. 

Making connections while the power source is turning ON may result in a fire or electric shock.

Warning

Connect the Spot Light to the Control 

Unit output connector.

Ground the FG terminal.

(Ground the FG terminal if the ground wire in 

the power cord is not grounded.)
Use a wire of approximately 0.5 to 1.25 mm

2

 

(AWG20 to AWG16) for the FG terminal.

Connect power cord to the AC inlet 

and wall socket.

Connect the external control cable if 

you perform the external control.

1

2

4

FG

Remote control

100-240V

50/60Hz 27VA

Output

Spot Light

1

4

External control cable

2

FG cable

3

Power cord

3

Installation

2

・振動が少ない、水平で安定している。
・埃が少ない、換気のよい。
・水、油、液、薬品、蒸気などが本製品にかからない。
・腐食性ガスや可燃性ガスがない。
・水道、湯沸かし器、加湿器、クーラー、ヒーター、

ストーブなどが近くにない。

・温度が急に変化しない。
・必ず接地できる。

※並べて設置する際は上方

50mm

以上、左右

20mm

以上の間隔をあけて設置してください。

底面固定

Coarse

Fine

L1

L2

Power

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

ゴム足をはずして固定します。

※下図に示す方向以外では固定しないでください。

固定方法

本製品と接続するケーブル類は高圧線や動力線と束ねると誤動作の原因となり
ます。できるだけ離して配線してください。

配線にあたっての注意

設置場所

4

設置のしかた

Coarse

Fine

L1

L2

Power

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

50mm

20mm

縦置き

C

o

a

rs

e

Fi

n

e

L1

L2

P

owe

r

1

2

3

4

5

6

7

8

9

10

11

12 1

3

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12 1

3

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12 1

3

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12 1

3

14

15

16

20mm

50mm

横置き

拡大図

固定ネジ穴

固定ネジ (M3)

( 挿入深さ

5mm

以下 )

( 締付けトルク

0.3N

m

以下 )

ゴム足固定穴

これを引き抜くと

ゴム足が取れます

ゴム足

側面固定

C

o

a

rs

e

Fi

n

e

L1

L2

P

owe

r

1

2

3

4

5

6

7

8

9

10

11

12 1

3

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12 1

3

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12 1

3

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12 1

3

14

15

16

横置き

この面を上にして固定

本体: 背面

固定ネジ穴

縦置き

固定板

( 板厚

1.6t

以上 )

On/Off

100-240V~

1

2

L1

Light

L2

L1

(FAN)

EXT

GND

固定ネジ (

M3

)

( 挿入深さ

5mm

以下 )

( 締付けトルク

0.3N

m

以下 )

以下の条件のところに設置してください。

設置場所によっては製品が故障する恐れがあります。

(

P22

 図面掲載)

注意

注意

Coarse

Fine

L1

L2

Power

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

1

2

3

4

5

6

7 8

9 10

11

12

13

14

15

16

ゴム足をはずして固定します。

拡大図

固定ネジ穴

固定ネジ (M3)

( 挿入深さ

5mm

以下 )

( 締付けトルク

0.3N

m

以下 )

ゴム足固定穴

これを引き抜くと

ゴム足が取れます

ゴム足

5

0

10

5

0

10

1

2

3

4

6

7

8

9 1

2

3

4

6

9

7

8

L2

Control

Range

Remote

Hi

Lo

Manual

Intensity

Power

L1

PJ-1505-2CA

Hi

5

0

10

5

0

10

1

2

3

4

6

7

8

9 1

3

4

6

9

7

8

L2

Control

Range

Remote

Lo

Manual

Intensity

Power

L1

PJ-1505-2CA

2

Hi

5

0

10

5

0

10

1

2

3

4

6

7

8

9 1

3

4

6

9

7

8

L2

Control

Range

Remote

Lo

Manual

Intensity

Power

L1

PJ-1505-2CA

2

5

5

3

4

6

7 3

4

6

Hi

0

10

0

10

1

2

8

9 1

9

7

8

L2

Control

Range Remote

Lo

Manual

Intensity

Power

L1

PJ-1505-2CA

2

Rubber foot

Rubber foot hole

Remove the screw.

Installation screw hole

Installation screw (M3)

Remove all of the rubber feet.

Insert M3 screws

*

 into the installation screw 

holes and secure them.

1

2

Securing the Bottom

In a flat and stable location with minimal vibration.
Well-ventilated places with minimal dust.
Places that are not subject to sudden temperature 
changes.

Places free from any water, oil, liquid, chemical or steam.
Places free from corrosive or combustible gas.
Places away from water faucets, boilers, humidifiers, air 
conditioners, heaters or stoves.

Please install the Control Unit in locations with following conditions.

Incorrect installation location may cause Control Unit failure.

Caution

*

Insert depth of 5 mm max.,  Tightening torque: 0.3 N•M max.

Front

Rear

The illustration shows the PJ-1505-2CA. The number of the intensity 
volumes, indicator lamps and output connectors depends on the 
number of the channels.

Remote Control

FG

100-240V~

50/60Hz 27VA

Output

PJ-1505-2CA

Power

Control

Remote

Manual

Range

Hi

Lo

L2

Intensity

L1

5

0

10

1

2

3

4

6

7

8

9

5

0

10

1

2

3

4

6

7

8

9

Remote control connector

AC inlet

Ground screw

Output connector

Remote/Manual switch

Intensity volume

Power switch

L1 Range switch

Indicator lamp

Pin No.

Signal

1

Input (Sense)

2

(+5.5 V)

3

Output-

Connector

SMP-03V-BC

Pin No.

Signal

Optional cable
Cable

color

Line

color

1

L1 Lighting ON/OFF control input (Turned OFF for +5 V input) Black

-

2

GND 

*

2

White

-

3

L2 Lighting ON/OFF control input (Turned OFF for +5 V input)

Red

-

4

L2 External potentiometer input

Green

-

5

L3 Lighting ON/OFF control input (Turned OFF for +5 V input) 

*

1 Yellow

-

6

L3 External intensity control analog input (0 to 5 V) 

*

1

Brown

-

7

L2 External intensity control analog input (0 to 5 V)

Blue

-

8

GND 

*

2

Purple

-

9

L1 External potentiometer input

Gray

-

10

L1 External intensity control analog input (0 to 5 V)

Pink

-

11

GND 

*

2

White

Black

12

L3 External potentiometer input 

*

1

Red

Black

13

Power supply for external potentiometer 
(+2.5 V, 3 mA max.)

Green Black

14

+5.5 V output (20 mA max.)

Yellow Black

15

GND 

*

2

Brown Black

-

Not connected

Blue

Black

Connector

1 2 3

1

2

3

An optional CCS external control cable EXCB2-B3 

(a 3 m long cable with a connector on one end) is sold 

separately.  The external control cable is a shielded cable.

*

1: NC (No-connection) is applied to the 2-channel unit.   

*

2: Internal common GND

Output connector

Remote control connector

11

10

9

14 15

13

12

3

2

1

6

7

8

5

4

Cable (Enlarged View)

Line color

Cable color

15-pin 

D-sub (plug)

M2.6mm 

screw

AC input models operate with 100 to 240 VAC. DC power input models operate with 24 VDC.

Models are available for either 2 channels or 3 channels.

The light intensity is controlled using a variable current control method.

The light intensity can be manually controlled by adjusting the intensity volume, or can be 

externally controlled using a PLC or image processing device.

The light intensity and lighting ON/OFF are controlled through external control.

The L1 range switch can be used for fine adjustment of the light intensity even in a low intensity range.

(Applicable only for the Spot Light connected to L1)

Features

Introduction

These products are dedicated Control Units to control the CCS LED Spot Lights HLV2/HLV Series.  

They are mainly used to control LED Spot Lights that are used for machine vision or industrial inspections. 

Do not use the Control Units for other applications, and be sure to follow the instructions below.

Under conditions or in an environment not described in this instruction guide.
In nuclear energy control systems, railroad systems, aviation systems, vehicles, combustion equipment, 
medical equipment, amusement machines, or safety equipment. 
In applications involving serious risk to life or property, particularly applications demanding a high level of safety.

Do not use the Control Unit in the following situations. 

Caution

Ite

m

s c

om

m

on t

o a
ll e

qu

ip

m

en

t

Do not place the Control Unit under direct sunlight 

or in a high humidity environment.  Doing so may 

result in fire due to internal temperature rise.

PROHIBITED

Be sure to ground the Control Unit before using 

it.  Not doing so may cause the Control Unit to 

malfunction due to static change.

MANDATORY

ACTIONS

Always place the Control Unit on a stable and flat location. Not 

doing so may result in the Control Unit falling or toppling, which 

may cause bodily injury and the Control Unit to malfunction.

PROHIBITED

Please use designated power sources with 

stable voltage. Sharing a power source with 

inverters, motors, etc. may cause malfunction.

MANDATORY

ACTIONS

Do not connect the Control Unit to the Spot Lights other 

than the applicable illuminators. Otherwise an over 

current may result in heating or fire. For information on the 

applicable illuminators, refer to 

5. Main Specifications

.

PROHIBITED

Make sure that connected Spot Light is within 

the power rating of the Control Unit. Not doing 

so may cause Control Unit failure.

MANDATORY

ACTIONS

Do not bend or jam cables when wiring the 

Control Unit. Doing so may cause Control Unit 

failure.

PROHIBITED

Make sure that the length of the extension cable is less than 

the specified length. For information on the cable length, 

refer to 

5. Main Specifications

. However, if the cable is too 

long, the light intensity will decrease due to voltage drop 

caused by the DC resistance of the cable.

MANDATORY

ACTIONS

Do not use user-made cables.  

Doing so may cause Control Unit failure.

PROHIBITED

Do not bundle the cables with high-voltage lines or power lines.  

Doing so may cause the Control Unit to malfunction. Keep the 

Control Unit cables as far away from such lines as possible.

MANDATORY

ACTIONS

To avoid Control Unit surface discoloration or 

deterioration, do not wipe the Control Unit with 

volatiles such as paint thinner or benzene.

PROHIBITED

Make sure to hold and pull from the plugs when 

disconnecting the cables. Not pulling from the plugs may 

damage the cable and result in fire or electric shock.

MANDATORY

ACTIONS

Use a dry cloth to remove dust or other foreign 

matter from the plug electrodes.  Failure to do 

so may result in fire. 

Before moving the Control Unit, disconnect 

cables. Damaging the cables may result in fire 

or electric shock.

MANDATORY

ACTIONS

When mount the unit in a system rack or case, the portion of the screws penetrating the case must be less than 

5 mm long.  If this portion is longer, internal components may be short-circuited.

MANDATORY

ACTIONS

A

C i

np

ut

Before use the power cord, make sure it satisfies the specification of the region where you are going to use.

100 to 120V range: SVT type or SJT type, AWG18, length: 3m max., dielectric strength: 125V min. 

200 to 240V range: H05VV-F type, AWG18, length: 3m max., dielectric strength: 250V min.

MANDATORY

ACTIONS

Plug the power cord directly into the wall socket.  

Please use the Control Unit within electricity 

voltage/current specifications. Otherwise it may 

cause fire and/or electric shock.

MANDATORY

ACTIONS

Keep metal objects, such as screwdrivers, away 

from the power cord plug. Otherwise, fire or an 

electric shock may result.

PROHIBITED

Do not damage or place heavy objects on 

power cord.  There are risks of damaging the 

cord, which may result in fire or electric shock.

PROHIBITED

Do not use the Control Unit if the plug on the 

cord is damaged or the wall socket is loose.  

Otherwise, fire or an electric shock may result.

PROHIBITED

D

C

 in

put

Verify polarity of terminals before connecting cables.  If polarity is reversed, it may cause fires or damage 

the equipment.

PROHIBITED

Warning

Ite

m

s c

om

m

on t

o a
ll e

qu

ipm

en

t

Do not disassemble or 

modify the Control Unit.  

Doing so may result in 

fire or electric shock.

DISASSEMBLY

PROHIBITED

Do not touch the Control 

Unit with wet hands.  

Doing so may result in 

electric shock.

DO NOT TOUCH

WITH WET HANDS

Make sure that the product is 

free of moisture or any liquid.  

Exposure to water may result in 

fire, electric shock, or product 

failure.

DO NOT SUBJECT 

TO MOISTURE

Do not touch the power 

cords during lightning.  

This may result in electric 

shock.

PROHIBITED

Turn off the power 

when connecting or 

disconnecting the Control 

Unit and peripherals.  

Otherwise it may cause 

fire and/or electric shock.

MANDATORY

ACTIONS

If abnormal condition occurs such 

as fuming, heat, smell, noise, or 

so on, stop using the Control Unit 

immediately, and turn off the power.  

A fire or electric shock may result if 

the Control Unit is kept used.

UNPLUG

Incorrect usage of the Control Unit may result in fire, electric shock, or other serious damages.  

Please ensure to follow the conditions below.

Warning

Indicates that incorrect usage may 

result in serious injury or death.

Caution

Indicates that incorrect usage may 

result in injury or property damage.

The following symbols are used in this instruction guide to indicate and classify the relative 

importance of warnings and cautions.

These symbols indicate prohibited actions.

These symbols indicate required actions.

DO NOT TOUCH

WITH WET HANDS

PROHIBITED

UNPLUG

MANDATORY

ACTIONS

DO NOT SUBJECT 

TO MOISTURE

DISASSEMBLY

PROHIBITED

The following symbols in the instruction guide indicate and classify the precautions.

Important Information for Equipment Safety

- Read Before Use -

Instruction Guide

Thank you for purchasing a CCS product.  To ensure proper use of the product, 
please read this instruction guide before use and keep it for your future reference.

Dedicsated Control Units for LED Spot Lights HLV2/HLV Series

P J

 

Series

Front View

If you use a self-made cable, use a 
shielded cable whose length is 3 m or 
less.

Reviews: