PROHIBITED
DISASSEMBLY
PROHIBITED
DO NOT TOUCH
WITH WET HANDS
DO NOT SUBJECT
TO MOISTURE
MANDATORY
ACTIONS
These symbols indicate prohibited actions. This symbol indicates required actions.
Thank you for purchasing a CCS product. To ensure proper use of the product,
please read this instruction guide before use and keep it for your future reference.
Flat Dome Lights
LFXV Series
The following symbols in the Instruction Guide indicate and classify the precautions.
The following symbols are used in this instruction guide to indicate and
classify the relative importance of warnings and cautions.
Warning
Indicates that incorrect
usage may result in serious
injury or death.
Caution
Indicates that incorrect
usage may result in injury
or property damage.
These products have been designed with full consideration of safety. However,
incorrect usage of the products may result in fire, electric shock, or other serious
damages. Please ensure to follow the conditions below.
Important Information for Equipment Safety
- Read Before Use -
1
Confirming Product Information
2
REATIN
G
Tag Example
Back
Front
M A D E I N J A P A N
M O D E L
I N P U T
S / N
L F X V - n n n R D
2 4 V = n n W
0 1 2 3 4 5 6 7 8 9
M a n u f a c t u r e r : C C S I n c .
3 7 4 O k a k u e n c h o , K a m i g y o - k u ,
K y o t o 6 0 2 - 8 0 1 1 , J a p a n
E U I m p o r t e r : C C S E u r o p e N . V .
B e r g e n s e s t e e n w e g 4 2 1 B ,
1 6 0 0 S i n t - P i e t e r s - L e e u w , B e l g i u m
REATING
The following tag is attached to the cable on the LED Light. The
color of the label indicates the luminescence color of the Light
Unit. The back of the tag there is a name label that gives the model
number, power consumption, and serial number. Be sure to check
the contents before using the Light Unit and handle the label with
care. If the label is missing or damaged and the contents cannot be
checked, please contact CCS Inc.
This Light Unit has both dome illumination and coaxial illumination
characteristics. To obtain the optimum images, refer to the following.
Category
Recommendation
Application
Visual
inspection
Optimal
Inspecting the appearance of curved, irregular, or flat
glossy objects (detecting scratches, dirt, scorching,
breaking, or chipping, distinguishing different shapes
and presence/absence, inspecting surface conditions)
Character
recognition
Suitable
Character recognition on glossy objects. Bar codes
and 2-dimensional codes.
Measurement
Usable
Dimensional measurement
Recommended Applications
Operating Instructions
5
Features
3
Use of diffused light
eliminates shadows in
curved surfaces or parts.
Highly reflective surface
is uniformly illuminated.
Characteristics for Dome Illumination
Characteristics for Coaxial Illumination
Warning
Do not disassemble or modify the
Light Unit. Doing so may result in
fire or electric shock.
DISASSEMBLY
PROHIBITED
LED Light radiation may cause
corneal or retinal abnormalities
if you look directly at the light. To
prevent harmful light exposure,
never look directly at the LED Light.
MANDATORY
ACTIONS
Do not touch the Light Unit with
wet hands. Doing so may result in
electric shock.
DO NOT TOUCH
WITH WET HANDS
This Light Unit generates high
temperatures. Do not touch the Light
Unit while it is turned on or immediately
after it is turned off, or burning may
result. Provide cooling with a fan or
other ventilation if the Light Unit is to
be used in a closed space.
MANDATORY
ACTIONS
Make sure that the Light Unit is free
of moisture or any liquid. Exposure
to water may result in fire, electric
shock.
DO NOT SUBJECT
TO MOISTURE
Connect or disconnect the light
cable only after turning off the
power source. Failure to do so
may result in circuit damage, fire
caused by a minute spark, or
electric shock.
MANDATORY
ACTIONS
If abnormal condition occurs such
as fuming, heat, smell, noise, or
so on, stop using the Light Unit
immediately, and turn off the power
source. A fire or electric shock may
result if the Light Unit is kept used.
MANDATORY
ACTIONS
Using Infrared Light Units
(LFXV-nnnIR860)
Make known to all personnel
concerned the risk of infrared
radiation. Failure to do so may
cause incorrect handling.
MANDATORY
ACTIONS
Caution
Do not use user-made cables. Doing
so may cause product failure. Use the
CCS extension cable if it is necessary
to extend the distance between the
Light Unit and the Control Unit.
PROHIBITED
Use Control Unit that is suitable
for the Light Unit ratings. Using an
incorrect Control Unit can cause
Light Unit failure.
MANDATORY
ACTIONS
Be careful of static electricity.
Damage to the LED Light may
occur, if a person charged with
static electricity touches it. Keep
the product away from all items
charged with static electricity.
PROHIBITED
Use a standard Extension Cable
that is manufactured by CCS.
However, if the cable is too long,
the light intensity will decrease due
to the DC resistance of the cable.
MANDATORY
ACTIONS
Do not drop the Light Unit or
subject it to impact. Doing so may
cause the Light Unit to malfunction.
PROHIBITED
Please install the Light Unit to locations with following conditions.
Incorrect installation location may cause Light Unit failure.
In a flat and stable location with
minimal vibration.
Well-ventilated places with minimal dust.
Places that are not subject to sudden
temperature changes.
Places free from any water, oil, liquid,
chemical, or steam.
Places free from corrosive or combustible gas.
Places away from water faucets, boilers,
humidifiers, air conditioners, heaters, or stoves.
Do not use the Light Unit in the following situations.
Under conditions or in an environment not described in this instruction guide.
In nuclear energy control systems, railroad systems, aviation systems, vehicles,
combustion equipment, medical equipment, amusement machines, or safety equipment.
In applications involving serious risk to life or property, particularly applications
demanding a high level of safety.
Instruction Guide
LED Light for Machine Vision
and Industrial Inspection
4 Installation
Read the instruction guide of the Control Unit before use.
MANDATORY
ACTIONS
Make sure that the Control Unit is turned OFF before connecting.
For information on applicable Control Units and cables, refer to the product
catalogs or the CCS website.
Connect the light cable of the Light Unit to the Control Unit.
1
Connect to the Control Unit equipped with
SMP-03V-BC
Connectors
for power output. Insert the plug all the way into the connector.
Using Infrared Light Units (LFXV-nnnIR860)
Do not expose human eyes to infrared radiation. Also, make
known to all personnel concerned the risk of infrared radiation.
Caution
Turn ON the Control Unit to turn ON the Light Unit.
2
This Light Unit has two faces. The surface affixed with a QR code
sticker must face the camera when you install the Light Unit.
Also, these two surfaces are identified by the difference in the
position of the screws. For information on the dimensions of each
part, refer to
8. Dimensions
.
QR code sticker
- 1 -